...
首页> 外文期刊>European radiology >Near-real time oculodynamic MRI: A feasibility study for evaluation of diplopia in comparison with clinical testing
【24h】

Near-real time oculodynamic MRI: A feasibility study for evaluation of diplopia in comparison with clinical testing

机译:近实时眼动MRI:评估复视与临床测试的可行性研究

获取原文
获取原文并翻译 | 示例

摘要

Objective: To demonstrate feasibility of near-real-time oculodynamic magnetic resonance imaging (od-MRI) in depicting extraocular muscles and correlate quantitatively the motion degree in comparison with clinical testing in patients with diplopia. Methods: In 30 od-MRIs eye movements were tracked in the horizontal and sagittal plane using a a TrueFISP sequence with high temporal resolution. Three physicians graded the visibility of extraocular muscles by a qualitative scale. In 12 cases, the maximal monocular excursions in the horizontal and vertical direction of both eyes were measured in od-MRIs and a clinical test and correlated by the Pearson test. Results: The medial and lateral rectus muscles were visible in the axial plane in 93% of the cases. The oblique, superior and inferior rectus muscles were overall only in 14% visible. Horizontal (p = 0,015) and vertical (p = 0,029) movements of the right eye and vertical movement of the left eye (p = 0,026) measured by od-MRI correlated positively to the clinical measurements. Conclusions: Od-MRI is a feasible technique. Visualization of the horizontal/vertical rectus muscles is better than for the superior/inferior oblique muscle. Od-MRI correlates well with clinical testing and may reproduce the extent of eye bulb motility and extraocular muscle structural or functional deteriorations. Key Points ? Oculodynamic MRI technique helps clinicians to assess eye bulb motility disorders ? MRI evaluation of eye movement provides functional information in cases of diplopia ? Oculodynamic MRI reproduces excursion of extraocular muscles with good correlation with clinical testing ? Dynamic MRI sequence supplements static orbital protocol for evaluation of motility disorders
机译:目的:证明近视眼动眼磁共振成像(od-MRI)在描述眼外肌中的可行性,并与复视患者的临床测试相比较,定量地确定运动程度。方法:在30次od-MRI中,使用具有高时间分辨率的TrueFISP序列在水平和矢状面中跟踪眼睛的运动。三名医师通过定性量表对眼外肌的可见性进行了分级。在12例中,在od-MRI和临床测试中测量了两只眼睛在水平和垂直方向上的最大单眼偏移,并通过Pearson测试进行了相关。结果:93%的病例在轴平面可见内侧和外侧直肌。斜肌,上直肌和下直肌总体上只有14%可见。 od-MRI测量的右眼水平运动(p = 0,015)和垂直运动(p = 0,029)和左眼垂直运动(p = 0,026)与临床测量结果呈正相关。结论:Od-MRI是一种可行的技术。水平/垂直直肌的可视化效果优于上/下斜肌。 Od-MRI与临床测试密切相关,并可能再现眼球运动性和眼外肌结构或功能退化的程度。关键点 ?眼动MRI技术可帮助临床医生评估眼球运动障碍?复视的情况下,对眼球运动的MRI评估可提供功能信息。眼动MRI可以再现眼外肌的偏移,与临床试验有很好的相关性?动态MRI序列补充了用于评估运动障碍的静态轨道方案

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号