首页> 外文期刊>European journal of vascular and endovascular surgery: the official journal of the European Society for Vascular Surgery >Comparison of 980 nm laser and bare-tip fibre with 1470 nm laser and radial fibre in the treatment of great saphenous vein varicosities: a prospective randomised clinical trial.
【24h】

Comparison of 980 nm laser and bare-tip fibre with 1470 nm laser and radial fibre in the treatment of great saphenous vein varicosities: a prospective randomised clinical trial.

机译:980 nm激光和裸露光纤与1470 nm激光和放射状光纤在大隐静脉曲张性静脉曲张治疗中的比较:一项前瞻性随机临床试验。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVES: The aim of this study is to compare efficacy, early postoperative morbidity and patient comfort of two laser wavelengths and fibre types in treatment of great saphenous vein (GSV) incompetence resulting in varicosities of the lower limb. DESIGN: Prospective randomised clinical trial. MATERIALS AND METHODS: Sixty patients (106 limbs) were randomised into two groups. They were treated with bare-tip fibres and a 980 nm laser in group 1 and radial fibres and 1470 nm laser in group 2 in order to ablate the GSV. Local pain, ecchymosis, induration and paraesthesia in treated regions, distance from skin, vein diameter, treated vein length, tumescent anaesthesia volume, delivered energy and patient satisfaction were recorded. Follow-up visits were planned on the 2nd postoperative day, 7th day, 1st, 2nd, 3rd and 6th months. RESULTS: Mean GSV diameters at saphenofemoral junction and knee levels were 12.1 S.D. 4.3 mm and 8.2 S.D. 2.4 mm, and 11.8 S.D. 4.1 mm and 7.9 S.D. 2.6 mm respectively in groups 1 and 2. There were 14 patients with induration, 13 with ecchymosis and nine minimal paraesthesia in group 1 and no or minimal local pain, minimum ecchymosis or induration in group 2. Duration of pain and need for analgesia was also lower in group 2 (p < 0.05). There was significant difference on postoperative day 2, day 7 and 1st month control in favour of group 2 in venous clinical severity scores (VCSS). CONCLUSION: Treatment of the GSV by endovenous laser ablation using a 1470 nm laser and a radial fibre resulted in less postoperative pain and better VCSS scores in the first month than treatment with a 980 nm laser and a bare-tip fibre.
机译:目的:本研究的目的是比较两种激光波长和纤维类型在治疗大隐静脉(GSV)功能不全导致下肢静脉曲张不全的疗效,术后早期发病率和患者舒适度。设计:前瞻性随机临床试验。材料与方法:将60例患者(106条肢体)随机分为两组。为了消融GSV,在第1组中分别用裸梢光纤和980 nm激光以及在第2组中使用放射状光纤和1470 nm激光进行处理。记录治疗区域的局部疼痛,瘀斑,硬结和感觉异常,与皮肤的距离,静脉直径,治疗的静脉长度,肿胀麻醉量,输送的能量和患者满意度。计划在术后第二天,第七天,第一,第二,第三和第六个月进行随访。结果:sa股交界处和膝关节平均GSV直径为12.1 S.D. 4.3毫米和8.2标准尺寸2.4毫米和11.8 S.D. 4.1毫米和7.9英寸标准尺寸第1组和第2组分别为2.6 mm。第1组有14例有硬结的患者,第13例有瘀斑和9例轻微的感觉异常,第2组没有或仅有很少的局部疼痛,最小的瘀斑或硬结。组2较低(p <0.05)。术后第2天,第7天和第1个月对照组的静脉临床严重程度评分(VCSS)有明显差异,而第2组更为明显。结论:与使用980 nm激光和裸露纤维的治疗相比,使用1470 nm激光和a骨纤维的静脉激光消融治疗GSV可使术后第一个月的术后疼痛减轻,VCSS评分更高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号