OBJECTIVE: to study various phosphors used in detectors of medical imaging systems by the gain transfer function (GTF), defined in terms of X-ray luminescence efficiency, light spectrum and modulation transfer function. MATERIALS AND METHODS: four phosphor materials, La(2)O(2)S:Tb, Y(2)O(2)S:Tb, Y(2)O(2)S:Eu and Y(2)O(3):Eu were used in the form of fluorescent layers prepared in the laboratory. The GTF was determined at 30 kVp and 80 kVp X-ray tube voltages for various phosphor coating weights. RESULTS: La(2)O(2)S:Tb, which was the highest density and effective atomic number phosphor used, was found to exhibit the best GTF performance at 80 kVp. At 30 kVp, the yttrium based phosphors were found of increased performance. This is mainly due to the proximity of the X-ray energy to the K-absorption edge of yttrium at 17 keV. Europium activated phosphors were found to perform very well when combined with the red sensitive film and the silicon photodiode. CONCLUSION: The GTF may be a useful method for comparing and selecting phosphor materials for use in various medical imaging applications.
机译:目的:通过X射线发光效率,光谱和调制传递函数定义的增益传递函数(GTF),研究医学成像系统探测器中使用的各种荧光粉。材料与方法:四种荧光粉材料,La(2)O(2)S:Tb,Y(2)O(2)S:Tb,Y(2)O(2)S:Eu和Y(2)O( 3):Eu以实验室制备的荧光层的形式使用。对于各种磷光体涂层重量,在30 kVp和80 kVp X射线管电压下确定GTF。结果:发现La(2)O(2)S:Tb是最高密度和有效原子序数的荧光粉,在80 kVp时表现出最佳的GTF性能。在30 kVp下,发现基于钇的荧光粉性能增强。这主要是由于X射线能量在17 keV处接近钇的K吸收边缘。发现with活化的磷光体与红敏膜和硅光电二极管结合使用时性能非常好。结论:GTF可能是比较和选择用于各种医学成像应用的荧光粉材料的有用方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号