首页> 外文期刊>European Journal of Radiology >Near-real-time feedback control system for liver thermal ablations based on self-referenced temperature imaging.
【24h】

Near-real-time feedback control system for liver thermal ablations based on self-referenced temperature imaging.

机译:基于自参考温度成像的肝脏热消融的近实时反馈控制系统。

获取原文
获取原文并翻译 | 示例
           

摘要

Our challenge was to design and implement a dedicated temperature imaging feedback control system to guide and assist in a thermal liver ablation procedure in a double-donut 0.5T open MR scanner. This system has near-real-time feedback capability based on a newly developed "self-referenced" temperature imaging method using "moving-slab" and complex-field-fitting techniques. Two phantom validation studies and one ex vivo experiment were performed to compare the newly developed self-referenced method with the conventional subtraction method and evaluate the ability of the feedback control system in the same MR scanner. The near-real-time feedback system was achieved by integrating the following primary functions: (1) imaging of the moving organ temperature; (2) on-line needle tip tracking; (3) automatic turn-on/off the heating devices; (4) a Windows operating system-based novel user-interfaces. In the first part of the validation studies, microwave heating was applied in an agar phantom using a fast spoiled gradient recalled echo in a steady state sequence. In the second part of the validation and ex vivo study, target visualization, treatment planning and monitoring, and temperature and thermal dose visualization with the graphical user interface of the thermal ablation software were demonstrated. Furthermore, MR imaging with the "self-referenced" temperature imaging method has the ability to localize the hot spot in the heated region and measure temperature elevation during the experiment. In conclusion, we have demonstrated an interactively controllable feedback control system that offers a new method for the guidance of liver thermal ablation procedures, as well as improving the ability to assist ablation procedures in an open MR scanner.
机译:我们的挑战是设计和实施专用的温度成像反馈控制系统,以指导和协助在双甜甜圈0.5T开放式MR扫描仪中进行热肝消融手术。该系统基于最新开发的使用“运动平板”和复杂场拟合技术的“自参考”温度成像方法,具有近实时的反馈能力。进行了两项幻像验证研究和一项离体实验,以将新开发的自参考方法与常规减法方法进行比较,并评估同一MR扫描仪中反馈控制系统的能力。通过整合以下主要功能实现了近实时反馈系统:(1)运动器官温度成像; (2)在线针尖跟踪; (3)自动开启/关闭加热装置; (4)一种基于Windows操作系统的新颖用户界面。在验证研究的第一部分中,以快速变质梯度回波在稳态序列中对琼脂模型进行微波加热。在验证和离体研究的第二部分中,演示了目标可视化,治疗计划和监控以及通过热消融软件的图形用户界面进行的温度和热剂量可视化。此外,使用“自参考”温度成像方法的MR成像具有在实验过程中定位加热区域中的热点并测量温度升高的能力。总之,我们已经展示了一种交互式可控制的反馈控制系统,该系统提供了一种指导肝热消融手术的新方法,并提高了在开放式MR扫描仪中辅助消融手术的能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号