首页> 外文期刊>AJNR. American journal of neuroradiology >Comparison between Dual-Energy CT and Quantitative Susceptibility Mapping in Assessing Brain Iron Deposition in Parkinson Disease
【24h】

Comparison between Dual-Energy CT and Quantitative Susceptibility Mapping in Assessing Brain Iron Deposition in Parkinson Disease

机译:双能CT与定量药化率图在帕金森病脑铁沉积评估中的比较

获取原文
获取原文并翻译 | 示例

摘要

Background and purpose: Both dual-energy CT and quantitative susceptibility mapping can evaluate iron depositions in the brain. The purpose of this study was to compare these 2 techniques in evaluating brain iron depositions in Parkinson disease. Materials and methods: Forty-one patients with Parkinson disease (Parkinson disease group) and 31 age- and sex-matched healthy controls (healthy control group) were included. All participants underwent brain dual-energy CT and quantitative susceptibility mapping. ROIs were set bilaterally in the globus pallidus, substantia nigra, red nucleus, caudate nucleus, and putamen. CT values and magnetic susceptibility values were obtained in each ROI. Differences in CT values and magnetic susceptibility values between the Parkinson disease and healthy control groups were compared, followed by analysis of receiver operating characteristic curves. Correlations between CT values and magnetic susceptibility values were then evaluated. Results: The CT values of the bilateral globus pallidus, substantia nigra, and red nucleus were higher in the Parkinson disease group (P < .05). The magnetic susceptibility values of the bilateral globus pallidus and substantia nigra were higher in the Parkinson disease group (P < .05). The CT value of the right globus pallidus in linear fusion images had the highest diagnostic performance (0.912). Magnetic susceptibility values of the bilateral globus pallidus in the Parkinson disease group were positively correlated with CT values at the level of 80 kV(peak), linear fusion images, and SN150 kV(p) (r = 0.466~0.617; all, P < .05). Conclusions: Both dual-energy CT and quantitative susceptibility mapping could assess excessive brain iron depositions in Parkinson disease, and we found a positive correlation between CT values and magnetic susceptibility values in the bilateral globus pallidus.
机译:背景和目的:双能 CT 和定量磁化率映射都可以评估大脑中的铁沉积。本研究的目的是比较这两种技术在评估帕金森病中脑铁沉积的作用。材料和方法:纳入41例帕金森病患者(帕金森病组)和31例年龄和性别匹配的健康对照(健康对照组)。所有参与者都接受了脑双能CT和定量磁化率图。ROI在苍白球、黑质、红核、尾状核和壳核中双侧设置。在每个ROI中获得CT值和磁化率值。比较帕金森病组和健康对照组CT值和磁化率值的差异,然后分析受试者工作特征曲线。然后评估 CT 值和磁化率值之间的相关性。结果:帕金森病组双侧苍白球、黑质、红核CT值较高(P <.05)。帕金森病组双侧苍白球和黑质磁化率值较高(P < .05)。线性融合图像中右侧苍白球的CT值具有最高的诊断性能(0.912)。帕金森病组双侧苍白球磁化率值与80 kV(峰值)CT值、线性融合图像和SN150 kV(p)均呈正相关(r = 0.466~0.617;均P < .05)。结论:双能CT和定量磁化率标测均能评估帕金森病患者脑铁沉积过多,双侧苍白球CT值与磁化率值呈正相关。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号