During 3 months storing of 50 percent KOH in a 40-m~3 cistern the content of iron in KOH increased above the allowed limit of 10 mg/1. The analysis of circumstances revealed that the only possible source for iron is corrosion of basic mate-rial and/or corrosion of welds. Chemical analysis of base material and weld confirmed that both corresponded to declared stainless steel AISI 316 Ti. Metallographic analysis showed the presence of martensite in the outer and inner surface layers with pitting and mtercrystalline corrosion. Shotblasting caused plastic deformation and the appearance of deformation induced martensite in both surface layers of the cistern. The presence of martensite diminished corrosion resistance and enabled the start of the corrosion process which increased the content of iron in 50 percent KOH during the storing period.
机译:在40-m〜3的水箱中储存50%的KOH的3个月中,KOH中的铁含量增加到允许的极限值10 mg / 1以上。对情况的分析表明,铁的唯一可能来源是基本材料的腐蚀和/或焊缝的腐蚀。基础材料和焊缝的化学分析证实,两者均符合已声明的AISI 316 Ti不锈钢。金相分析表明,外表面和内表面存在马氏体,具有点蚀和多晶腐蚀。喷砂在水箱的两个表层均引起塑性变形,并出现变形诱发马氏体。马氏体的存在降低了耐腐蚀性,并使腐蚀过程开始,从而在储存期间增加了50%KOH中的铁含量。