A Polyester plant is using Proprietary heat exchange fluids (26.5% biphenyl, 73.5% diphe-nyloxide). The plant hot condensate tank, condensate feed tank, and heat exchanger vapor phase dead end and ventable lines (ASTM 106 Grade B) with isolation valves were suffering frequent leakages with severe gouging and pitting corrosion. Lustrous (shiny) coke deposit was prominent inside the cut sections due to coke formation by low boiler products. Some adhered brown iron oxide (rust) deposits were also visible. A sludge sample was analyzed by XRD which revealed that carbon was the major constituent with gamma-Maghemite-C (an iron oxide) as second mineral in order of abundance. The failure was diagnosed as severe localized corrosion and gouging at temperatures of about 200 deg C and 53 psi by non-condensable low boilers decomposed corrosive products. The remedy was suggested which has been validated over the 2 years trouble free performance.
机译:一家聚酯厂正在使用专有的热交换液(26.5%的联苯,73.5%的二氧化乙烯)。工厂的热冷凝水箱,冷凝水进料箱以及带有隔离阀的热交换器气相死角和可排气管路(ASTM 106 B级)经常发生渗漏,严重气刨和点蚀。由于低沸点锅炉产品形成的焦炭,在切割区域内有光泽的(发光的)焦炭沉积物突出。还可以看到一些粘附的棕色氧化铁(铁)沉积物。通过XRD对污泥样品进行分析,结果表明碳是主要元素,γ-磁赤铁矿-C(一种氧化铁)是第二种矿物(按含量顺序)。通过不可冷凝的低沸点锅炉分解腐蚀性产物,在200摄氏度和53磅/平方英寸的温度下,故障被诊断为严重的局部腐蚀和气刨。建议的补救措施已在两年的无故障运行中得到验证。