首页> 外文期刊>Engineering failure analysis >Failure analysis of a high mast lamp post
【24h】

Failure analysis of a high mast lamp post

机译:高杆灯柱故障分析

获取原文
获取原文并翻译 | 示例
           

摘要

The failure of a high mast lamp post was analysed. The mast failed by bending at a position just opposite to the maintenance pocket. It appears that the failure was due to wind load, which the structure could not bear. The elemental analysis and mechanical properties determination of the failed mast materials was as per the recommended values. However, the mechanical properties were slightly higher compare to recommended values and this is because of the presence of very fine pearlite in the microstructure. The probable causes might be due to faulty installation and/or damage during installation, severe weather condition or events such as high-speed storm, etc. or fatigue caused by the unpredictable phenomenon of harmonic vibration.
机译:分析了高桅杆灯柱的故障。桅杆由于在与维护袋相对的位置弯曲而失效。看来故障是由于风荷载引起的,该结构无法承受。失效的桅杆材料的元素分析和力学性能确定均符合建议值。但是,机械性能比推荐值略高,这是因为在微结构中存在非常细的珠光体。可能的原因可能是由于错误的安装和/或安装过程中的损坏,恶劣的天气条件或诸如高速风暴等事件或由于不可预期的谐波振动现象引起的疲劳。