The Use of Postoperative Slit-Lamp Optical CoherenceTomography to Predict Primary Failure in DescemetStripping Automated Endothelial Keratoplasty

机译:术后裂隙灯光学相干断层扫描术在预测DescemetStripping内皮自动角膜移植术中的主要失败中的应用

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To determine if central donor lenticle thick' ness as measured by slit-lamp optical coherence tomog-raphy (SL OCT; Heidelberg Engineering, Heidelberg, Germany) is predictive of primary donor failure in patients undergoing Descemet stripping automated endothelial keratoplasty (DSAEK).;DESIGN: Retrospective cross-sectional study.;METHODS: Eighty-four patients who underwent DSAEK surgery by 2 surgeons (D.C.R. and J.A.S.) were enrolled. At each postoperative visit (postoperative day 1, week 1, month 1, and month 2), an SL OCT scan was obtained. Statistical differences in SL OCT measurements of successful and failed DSAEK procedures were measured using the Student t test. A successful DSAEK surgery was defined as having an anatomically attached, clear recipient corneal stroma and donor lenticle compatible with good vision 2 months after surgery. A failed DSAEK surgery was defined as an attached donor lenticle with SL evidence of corneal edema and thickening visible at 2 months or more.;RESULTS: Ninety-three eyes of 84 consecutive patients who underwent DSAEK surgery also underwent postoperative SL OCT. After 2 months of follow-up, 82 (88%) procedures were successful and 11 (12%) procedures were failures. The average donor lenticle thickness in successful DSAEK eyes was 314 +- 128 mum on postoperative day 1 as compared with failed DSAEK eyes, which averaged 532 +- 259 mum (P = .0013). This was independent regardless of whether the lenticle was attached on the first postoperative visit. Seventy-nine (98%) successful DSAEK eyes had a lenticle thickness of <= 350 mum at the 1-week visit. All of the failed DSAEK eyes (11 eyes) had a lenticle thickness >= 350 mum at the 1-week postoperative visit. Statistically significant differences in SL OCT thickness measurements were seen between successful and failed DSAEK cases at all examinations after postoperative week 1. ;CONCLUSIONS: Corneal thickness measurements made with SL OCT are an important predictor of DSAEK failure in both attached and detached lenticles within the first week of surgery. DSAEK lenticle thickness of 350 mum or less at 1 week had a predictability of success of more than 98%.
机译:目的:确定通过裂隙灯光学相干断层扫描(SL OCT; Heidelberg Engineering,Heidelberg,德国)测量的中央供体双凸透镜厚度是否预示着进行Descemet剥离自动内皮角膜成形术(DSAEK)的患者的原发性供体衰竭设计:回顾性横断面研究方法:招募了由2位外科医生(DCR和JAS)进行DSAEK手术的84例患者。每次术后访视(术后第1天,第1周,第1个月和第2个月),均进行SL OCT扫描。使用Student t检验测量成功和失败DSAEK程序的SL OCT测量的统计差异。成功的DSAEK手术定义为术后2个月具有解剖学附着,清晰的受体角膜基质和供体双凸透镜,且视野良好。 DSAEK手术失败的定义是附着的供体双凸透镜,在2个月或更长时间内可见SL的角膜水肿和增厚迹象。随访2个月后,成功进行了82次(88%),失败了11次(12%)。术后第1天,成功的DSAEK眼的平均供体双凸透镜厚度为314±128微米,而失败的DSAEK眼的平均供体双凸透镜厚度为532±259毫米(P = 0.0013)。这是独立的,无论术后第一次访视时是否附有双凸透镜。在1周的访问中,有79例(98%)成功的DSAEK眼睛的凸透镜厚度小于或等于350微米。在术后1周就诊时,所有DSAEK失败的眼睛(11眼)的凸透镜厚度均大于等于350微米。在术后1周后的所有检查中,成功和失败的DSAEK病例之间SL OCT厚度测量值在统计学上均存在显着差异。手术一周。 1周时DSAEK透镜厚度小于或等于350毫米时,成功的可预测性超过98%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号