首页> 外文期刊>Electrophoresis: The Official Journal of the International Electrophoresis Society >Electromembrane extraction of heavy metal cations followed by capillary electrophoresis with capacitively coupled contactless conductivity detection.
【24h】

Electromembrane extraction of heavy metal cations followed by capillary electrophoresis with capacitively coupled contactless conductivity detection.

机译:用电膜萃取重金属阳离子,然后通过毛细管电泳进行电容耦合非接触电导检测。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Electromembrane extraction (EME) was used as an off-line sample pre-treatment method for the determination of heavy metal cations in aqueous samples using CE with capacitively coupled contactless conductivity detection (CE-C(4) D). A short segment of porous polypropylene hollow fibre was penetrated with 1-octanol and 0.5% v/v bis(2-ethylhexyl)phosphonic acid and constituted a low cost, single use, disposable supported liquid membrane, which selectively transported and pre-concentrated heavy metal cations into the fibre lumen filled with 100 mM acetic acid acceptor solution. Donor solutions were standard solutions and real samples dissolved in deionized water at neutral pH. At optimized EME conditions (penetration time, 5 s; applied voltage, 75 V; and stirring rate, 750 rpm), 15-42% recoveries of heavy metal cations were achieved for a 5 min extraction time. Repeatability of the EME pre-treatment was examined for six independent EME runs and ranged from 6.6 to 11.1%. Limits of detection for the EME-CE-C(4) D method ranged from 25 to 200 nM, resulting into one to two orders of magnitude improvement compared with CE-C(4) D without sample treatment. The developed EME sample pre-treatment procedure was applied to the analysis of heavy metal cations in tap water and powdered milk samples. Zinc in the real samples was identified and quantified in a background electrolyte solution consisting of 20 mM L-histidine and 30 mM acetic acid at pH 4.95 in about 3 min.
机译:电膜萃取(EME)用作离线样品预处理方法,使用带有电容耦合非接触电导检测功能的CE(CE-C(4)D)测定水性样品中的重金属阳离子。一小段多孔聚丙烯中空纤维被1-辛醇和0.5%v / v双(2-乙基己基)膦酸渗透,并构成了一种低成本,一次性使用的一次性支撑液膜,可选择性地运输和预浓缩重质金属阳离子注入充满100 mM乙酸受体溶液的纤维腔中。供体溶液是标准溶液,实际样品溶于中性pH的去离子水中。在优化的EME条件下(渗透时间为5 s;施加电压为75 V;搅拌速度为750 rpm),在5分钟的萃取时间内,重金属阳离子的回收率达到15-42%。针对六个独立的EME运行检查了EME预处理的可重复性,范围为6.6%至11.1%。 EME-CE-C(4)D方法的检出限范围为25到200 nM,与未经样品处理的CE-C(4)D相比,检测限提高了一到两个数量级。发达的EME样品预处理程序用于自来水和奶粉样品中的重金属阳离子分析。在约3分钟内,在pH值为4.95的由20 mM L-组氨酸和30 mM乙酸组成的背景电解质溶液中鉴定和定量真实样品中的锌。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号