首页> 外文期刊>Investigative radiology >Comparison of a New Recirculation Thrombectomy Catheter With Other Devices of the Same Type: In Vitro and In Vivo Evaluations.
【24h】

Comparison of a New Recirculation Thrombectomy Catheter With Other Devices of the Same Type: In Vitro and In Vivo Evaluations.

机译:新型再循环血栓切除术导管与相同类型其他设备的比较:体内和体内评估。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Qian Z, Kvamme P, Raghed D, et al. Comparison of a new recirculation thrombectomy catheter with other devices of the same type: in vitro and in vivo evaluations. Invest Radiol 2002;37:503-511.RAIONALE AND OBJECTIVES To compare a new 7 Fr. Helix thrombectomy catheter with Amplatz thrombectomy devices (ATD) with respect to clot fragmentation efficiency, hemolytic potential, and risk for vascular trauma.MATERIALS AND METHODS Particle size was evaluated following the maceration of 8-to-10-day-old clots, each weighing 6 +/- 0.01 g. The clots were macerated using devices of various sizes, including the 7-Fr. Helix thrombectomy catheter, the 7-Fr. over-the-wire (OTW), 8-Fr. ATD and the 6-Fr. ATD. The number of particles by weight was quantified. The 7-Fr. Helix and the 8-Fr. ATD were tested in the native iliac vein of six dogs without presence of clots. Blood samples were obtained before, during, and at 1, 3, 6, 24, and 48 hours after the procedure, to monitor the hemolytic effects. The treated iliac veins were examined histologically.RESULTS Most of the clot was fragmented into particles <10 &mgr;m. The mean percentage by weight of the original clot that remained as particles larger than10 &mgr;m was 1.59% in the 7-Fr. Helix group. This was significantly less than 3.10% with the 6-Fr. ATD, 2.57% with 7-Fr. OTW and 2.44% in the 8-Fr. ATD group (<0.01). In vivo results showed a higher plasma free hemoglobin (PFH) level starting 5 minutes after initiating the ATD activation, reaching its peak after completion of the activation, and declining afterward, with return to the baseline at 24 hours. The haptoglobin level tended to decline slightly at 10 minutes, reaching its lowest level at 24 hours, and starting to recover at 48 hours. A similar pattern of PFH and haptoglobin changes was found in both groups. There were no significant differences regarding hemolytic effect of the two tested devices. No significant changes of creatinine were observed for up to 48 hours after procedures. Focal microthrombosis was seen in two sites of two vessels treated with the 7-Fr. Helix and a focal injury of a venous valve was noted in the 8-Fr. ATD group. The media and internal elastic lamina (IEL) were intact in all cases.CONCLUSION The newly designed 7-Fr. Helix is more effective in fragmentation in vitro clots than the 6 Fr. ATD, 7-Fr. OTW and the 8-Fr. ATD. The 7-Fr. Helix and the 8-Fr. ATD produced hemolytic effects, but they appeared to be tolerated by the animals. The in vivo results indicated that the 7-Fr. Helix appears to be as safe as the 8-Fr. ATD.
机译:Qian Z,Kvamme P,Raghed D等。新型再循环血栓切除术导管与相同类型的其他设备的比较:体外和体内评估。 Invest Radiol 2002; 37:503-511.RAIONALE和目标比较新的7Fr。螺旋血栓切除术导管与Amplatz血栓切除术装置(ATD)在血凝块破碎效率,溶血潜力和血管外伤风险方面的关系。材料与方法在浸没8至10天大的血凝块后评估颗粒大小,每次称重6 +/- 0.01克使用包括7-Fr在内的各种尺寸的设备浸没血块。螺旋血栓切除术导管,7-Fr。线控(OTW),8-Fr。 ATD和6-Fr。 ATD。定量按重量计的颗粒数。 7楼。螺旋线和8-Fr。在没有凝块存在的六只狗的native静脉中测试了ATD。在手术前,手术中,手术后1、3、6、24和48小时获取血液样本,以监测溶血作用。结果:大部分血块被破碎成<10μm的颗粒。在7-Fr中,大于10μm的颗粒保留的原始凝块的平均重量百分比为1.59%。螺旋组。对于6-Fr,这明显小于3.10%。 ATD:2.5-7%(含7-Fr)。 OTW和8-Fr中的2.44%。 ATD组(<0.01)。体内结果显示,在启动ATD激活后5分钟开始,血浆游离血红蛋白(PFH)的水平较高,在激活完成后达到其峰值,然后下降,并在24小时恢复到基线。触珠蛋白水平倾向于在10分钟时略有下降,在24小时时达到最低水平,并在48小时时开始恢复。两组均发现了相似的PFH和触珠蛋白变化模式。关于两种测试装置的溶血作用没有显着差异。手术后长达48小时未观察到肌酐的明显变化。在用7-Fr处理的两个血管的两个部位发现了局灶性微血栓形成。在8-Fr中发现了螺旋和静脉瓣的局灶性损伤。 ATD组。在所有情况下,中层和内部弹性薄片(IEL)均完好无损。结论新设计的7-Fr。螺旋比6 Fr更能有效地破碎体外血块。 ATD,7-Fr。 OTW和8-Fr。 ATD。 7楼。螺旋线和8-Fr。 ATD产生溶血作用,但它们似乎被动物所耐受。体内结果表明是7-Fr。螺旋线似乎和8-Fr一样安全。 ATD。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号