PURPOSE: To develop a 3.0 Tesla breast imaging protocol that combines high temporal and spatial resolution three-dimensional MR sequences for quantitative time course and morphologic analysis of breast lesions. MATERIALS AND METHODS: Thirty-four patients were included in the study (age range, 31-82; mean age, 54.3). The study protocol was approved by the Institutional Review Board and written informed consent was obtained from all patients. The magnetic resonance imaging protocol included: a coronal T1-weighted volume-interpolated-breathhold-examination sequence, focused on high temporal resolution for optimal assessment of the contrast-enhancement behavior of lesions (SI 1.7 mm isotropic; TA 3.45 minutes for 17 measurements); a coronal T1-weighted turbo fast-low-angle-shot-three-dimensional sequence, with water-excitation and fat suppression, focused on high spatial resolution for morphologic analysis (SI 1 mm isotropic; TA 2 minutes); and a repeated coronal volume-interpolated-breathhold-examination sequence for detection of washout. Lesion size and morphology were assessed. Region-of-interests for suspicious areas were manually drawn and evaluated for contrast-enhancement behavior by plotting intensity courses against time. Sensitivity and specificity with a 95% confidence interval and the negative predictive value and positive predictive value were calculated. Diagnostic accuracy was assessed. The histopathological diagnoses were used as a standard of reference. RESULTS: Fifty-five lesions were detected in 34 patients. All malignant breast lesions were identified correctly. There were 5 false-positive lesions. The sensitivity of contrast-enhanced magnetic resonance imaging of the breast at 3 T was 100%, with a 95% confidence interval (CI) of 90.6% to 100%. The specificity was 72.2%, with a 95% CI of 49.1% to 87.5%. The positive predictive value was 0.88 and the negative predictive value was 1. Diagnostic accuracy was 91% with a 95% CI of 80.4% to 96.1%. CONCLUSION: Our prospective study demonstrates that the presented 3 Tesla MR imaging protocol, comprising both high temporal and high spatial resolution, enables accurate detection and assessment of breast lesions.
机译:目的:开发一个3.0特斯拉乳腺成像协议,该协议结合了高时间和空间分辨率的三维MR序列,用于定量分析乳腺病变的时间过程和形态。材料与方法:该研究纳入了34例患者(年龄范围31-82;平均年龄54.3)。研究方案已获得机构审查委员会的批准,并获得了所有患者的书面知情同意。磁共振成像协议包括:冠状T1加权体积插值呼吸暂停检查序列,专注于高时间分辨率,以最佳评估病变的对比增强行为(SI 1.7 mm各向同性; TA 3.45分钟,用于17次测量) ;冠状T1加权涡轮快速低角度射击三维序列,具有水激发和脂肪抑制作用,专注于高空间分辨率的形态分析(SI 1 mm各向同性; TA 2分钟);以及重复的冠状动脉插值呼吸检查程序,以检测冲刷情况。评估病变大小和形态。手动绘制可疑区域的感兴趣区域,并通过绘制强度随时间变化的曲线来评估对比度增强行为。计算出置信区间为95%的敏感性和特异性,以及阴性预测值和阳性预测值。评估诊断准确性。组织病理学诊断用作参考标准。结果:34例患者中发现了55个病变。正确鉴别出所有恶性乳腺病变。有5个假阳性病变。在3 T时乳房的对比增强磁共振成像的灵敏度为100%,95%的置信区间(CI)为90.6%至100%。特异性为72.2%,95%CI为49.1%至87.5%。阳性预测值为0.88,阴性预测值为1。诊断准确性为91%,95%CI为80.4%至96.1%。结论:我们的前瞻性研究表明,提出的3 Tesla MR成像方案(包括高时间分辨率和高空间分辨率)能够准确检测和评估乳腺病变。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号