首页> 外文期刊>Investigative ophthalmology & visual science >Dynamic Contour Tonometry in Comparison to Intracameral IOP Measurements.
【24h】

Dynamic Contour Tonometry in Comparison to Intracameral IOP Measurements.

机译:动态轮廓眼压计与前房内眼压测量的比较。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: The purpose of the study was to examine the effect of central corneal thickness (CCT), corneal curvature, astigmatism, axial length (AL), and age on measurements with the Pascal Dynamic Contour Tonometer (DCT). METHODS: In a prospective clinical trial 75 eyes of 75 patients undergoing phacoemulsification were examined. Before phacoemulsification, the anterior chamber was cannulated at the temporal corneal limbus. In a closed system the IOP was directly set to 15, 20, or 35 mm Hg with a manometric water column. IOP measurements taken by DCT were compared to intracameral measurements with a precision reference pressure sensor. RESULTS: Measurements from 60 patients were suitable for statistical analysis. At IOP of 15 mm Hg, the mean difference between IOP measured by DCT and intracameral IOP was -0.02 +/- 1.32 mm Hg; at 20 mm Hg it was -0.2 +/- 1.44 mm Hg and at 35 mm Hg, -0.84 +/- 1.90 mm Hg. The concordance coefficient according to Lin was 0.9763, showing good agreement between DCT- and intracamerally measured IOP. There was a statistically significant correlation between the difference in IOP measured by DCT minus intracameral IOP and CCT (P = 0.0291, R(2) = 0.00012). All other parameters had no statistically significant effect on the difference between DCT and intracameral IOP (corneal curvature, P = 0.6094, R(2) = 0.00367; age, P = 0.9198, R(2) = 0.000003; astigmatism, P = 0.1564, R(2) = 0.08497; and axial length, P = 0.9484, R(2) = 0.00008). CONCLUSIONS: Measurements with the DCT showed good concordance with intracameral IOP. CCT exerted a statistically significant but clinically irrelevant effect on measurements with the DCT.
机译:目的:本研究的目的是检查中央角膜厚度(CCT),角膜曲率,散光,轴向长度(AL)和年龄对使用Pascal动态轮廓眼压计(DCT)进行测量的影响。方法:在一项前瞻性临床试验中,检查了75例行超声乳化术的患者中的75眼。在超声乳化术之前,前房在颞角膜缘处插管。在密闭系统中,使用测压水柱将IOP直接设置为15、20或35 mm Hg。将DCT进行的IOP测量与使用精密参考压力传感器进行的前房测量进行比较。结果:60例患者的测量值适合进行统计分析。在IOP为15 mm Hg时,DCT测量的IOP与前房IOP之间的平均差为-0.02 +/- 1.32 mm Hg;在20 mm Hg时为-0.2 +/- 1.44 mm Hg,在35 mm Hg时为-0.84 +/- 1.90 mm Hg。根据Lin得出的一致性系数为0.9763,表明DCT和椎间测量的IOP之间具有良好的一致性。 DCT减去前房内IOP与CCT测得的IOP差异之间存在统计学上的显着相关性(P = 0.0291,R(2)= 0.00012)。所有其他参数对DCT和前房内IOP之间的差异均无统计学意义(角膜曲率,P = 0.6094,R(2)= 0.00367;年龄,P = 0.9198,R(2)= 0.000003;散光,P = 0.1564, R(2)= 0.08497;轴向长度P = 0.9484,R(2)= 0.00008)。结论:DCT的测量显示与前房内眼压具有良好的一致性。 CCT对DCT的测量具有统计学意义,但在临床上不相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号