Intra- and extra-Articular planes of reference for use in total hip arthroplasty: A preliminary study

机译:用于全髋关节置换术的关节内和关节外参考平面:初步研究

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose Acetabular component malalignment in total hip arthroplasty can lead to potential complications such as dislocation, component impingement and excessive wear. Computer-assisted orthopaedic surgery systems generally use the anterior pelvic plane (APP). Our aim was to investigate the reliability of anatomical landmarks accessible during surgery and to define new potential planes of reference. Methods Three types of palpations were performed: virtual, on dry bones and on two cadaveric specimens. Four landmarks were selected, the reproducibility of their positioning ranging from 0.9 to 2.3 mm. We then defined five planes and tested them during palpations on two cadaveric specimens. Results Two planes produced a mean orientation error of 5.0° [standard deviation (SD 3.3°)] and 5.6° (SD 2.7°). Conclusions Even if further studies are needed to test the reliability of such planes on a larger scale in vivo during surgery, these results demonstrated the feasibility of defining a new plane of reference as an alternative to the APP.
机译:目的全髋关节置换术中髋臼组件错位可能导致潜在的并发症,例如脱位,组件撞击和过度磨损。计算机辅助骨科手术系统通常使用骨盆前平面(APP)。我们的目的是研究手术期间可访问的解剖标志的可靠性,并定义新的潜在参考平面。方法进行三种类型的触诊:虚拟的,干骨的和两个尸体标本。选择了四个界标,其定位的可复制性范围为0.9到2.3 mm。然后,我们定义了五个平面,并在两个尸体标本上进行触诊时对其进行了测试。结果两个平面产生的平均定向误差为5.0°(标准偏差(SD 3.3°))和5.6°(SD 2.7°)。结论即使需要进行进一步的研究以在手术期间在体内更大规模地测试此类平面的可靠性,这些结果也证明了定义新的参考平面作为APP的替代方案的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号