首页> 外文期刊>British Journal of Radiology >Comparison between coronal reformatted images and direct coronal CT images of the swine lung specimen: assessment of image quality with 64-detector row CT.
【24h】

Comparison between coronal reformatted images and direct coronal CT images of the swine lung specimen: assessment of image quality with 64-detector row CT.

机译:猪肺标本的冠状位重新格式化图像与直接冠状位CT图像之间的比较:用64探测器行CT评估图像质量。

获取原文
获取原文并翻译 | 示例
           

摘要

The aims of this study were to compare the image quality of coronal multiplanar reconstruction (MPR) images from axial spiral images with that of direct coronal spiral and sequential images, and to estimate and analyse the effect of an incremental change on the image quality using 64-detector row CT. 12 swine lungs were used. Five kinds of images from each lung specimen were obtained using 64-detector row CT. All images were analysed by categories and grades, and the direct coronal sequential images were used as the reference standard for the image quality. Statistical analysis was performed for the following categories: (i) inter-observer reliability, (ii) interaction between the observers and images, (iii) image analysis, (iv) anatomical structural analysis of each observer, (v) stair-step artefact and (vi) background noise. The overall image quality and the image quality of all anatomical structures of coronal MPR images with 0.67 mm slice increments were inferior to the image quality of the other images; this difference was statistically significant (p<0.05). Stair-step artefact was detected on coronal MPR images, and was more prominent on coronal MPR images with 0.67 mm slice increments than on coronal MPR images with 0.34 mm slice increments. The most severe background noise was detected on the direct coronal sequential images, but there was no significant difference between the direct coronal sequential images and the direct coronal spiral images. Background noise was least prominent on coronal MPR images with 0.67 mm slice increments. The increment process is important for improving the image quality of MPR images even when using 64-detector row CT. Coronal MPR images with 0.34 mm slice increments using 64-detector row CT showed a similar image quality to that obtained from the direct coronal images, and can be used instead. This means that the coronal MPR images obtained with 64-detector row CT could be as useful for evaluating the lung parenchyma as the axial high-resolution CT images.
机译:这项研究的目的是比较轴向螺旋图像与直接冠状螺旋图像和顺序图像的冠状多平面重建(MPR)图像的图像质量,并使用64估计和分析增量变化对图像质量的影响-探测器行CT。使用了12只猪肺。使用64个探测器行CT从每个肺部标本中获得了五种图像。所有图像按类别和等级进行分析,并且直接冠状连续图像被用作图像质量的参考标准。对以下类别进行了统计分析:(i)观察者之间的可靠性,(ii)观察者与图像之间的相互作用,(iii)图像分析,(iv)每个观察者的解剖结构分析,(v)阶梯假象(vi)背景噪音。具有0.67 mm切片增量的冠状MPR图像的整体图像质量和所有解剖结构的图像质量均次于其他图像;这种差异具有统计学意义(p <0.05)。在冠状MPR图像上检测到阶梯状伪​​影,并且在具有0.67 mm切片增量的冠状MPR图像上比在具有0.34 mm切片增量的冠状MPR图像上更加突出。在直接冠状连续图像上检测到最严重的背景噪声,但是在直接冠状连续图像和直接冠状螺旋图像之间没有显着差异。背景噪声在带有0.67 mm切片增量的冠状MPR图像上最不明显。即使使用64个检测器行CT,增量过程对于提高MPR图像的图像质量也很重要。使用64个探测器行CT以0.34 mm切片增量的冠状MPR图像显示的图像质量与直接冠状图像获得的图像质量相似,可以代替使用。这意味着用64排CT扫描获得的冠状MPR图像与轴向高分辨率CT图像一样,可用于评估肺实质。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号