Radiographic measurements are commonly used to quantify the treatment results of hip dysplasia and assess further need of operative treatment. We investigated the interobserver and intraobserver reliability of the commonest radiographic techniques in the assessment of hip dysplasia in skeletally mature adults. Three observers independently analysed 100 hip radiographs of patients with hip dysplasia aged between 16 and 32 years. We measured centre-edge angle of Wiberg, acetabular angle of Sharp, acetabular index of the weightbearing zone, acetabular index of depth to width, ACM-angle, MZ-distance, acetabular head index, lateral subluxation and neck-shaft angle. In addition, the radiographs were reviewed a second time 3 months apart by two of the observers to assess intraobserver reliability. We found a high correlation (intraclass correlation coefficient) for interobserver reliability (0.76-0.87) and intraobserver reliability (0.70-0.92) for all radiographic measurements except acetabular index of depth to width, ACM-angle and MZ-distance. Depending on the clinical question we therefore recommend the use of one of the reliable measurements to assess the radiograph of a dysplastic hip.
机译:射线照相术通常用于量化髋关节发育不良的治疗结果并评估进一步的手术治疗需求。我们调查了骨骼最成熟的成年人髋关节发育不良中最常见的放射线照相技术的观察者间和观察者内可靠性。三名观察员独立分析了100例年龄在16至32岁之间的髋关节发育不良患者的X光片。我们测量了Wiberg的中心边缘角度,Sharp的髋臼角度,承重区的髋臼指数,深度与宽度之间的髋臼指数,ACM角度,MZ距离,髋臼头指数,横向半脱位和颈轴角度。此外,两名观察员隔三个月对射线照相进行了第二次检查,以评估观察员的可靠性。我们发现,除髋臼纵深与宽度,ACM角度和MZ距离指标外,所有射线照相测量的观察者之间可靠性(0.76-0.87)和观察者内部可靠性(0.70-0.92)具有高度相关性(类内相关系数)。因此,根据临床问题,我们建议使用一种可靠的测量方法来评估髋关节发育不良的放射照片。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号