首页> 外文期刊>British journal of ophthalmology >Measurement error of visual field tests in glaucoma.
【24h】

Measurement error of visual field tests in glaucoma.

机译:青光眼视野检查的测量误差。

获取原文
获取原文并翻译 | 示例
       

摘要

AIM: Psychophysical strategies designed for clinical visual field testing produce rapid estimates of threshold with relatively few stimulus presentations and so represent a trade-off between test quality and efficiency. The aim of this study was to determine the measurement error of a staircase algorithm similar to full threshold with standard automated perimetry (SAP) and frequency doubling perimetry (FDP) in glaucoma patients. METHODS: Seven patients with early open angle glaucoma (OAG) were prospectively recruited. All were experienced in laboratory based psychophysics. Three matched test locations were examined with SAP (externally driven Humphrey field analyser) and FDP (CRT) in a single arbitrarily selected eye of each subject. Each location was tested twice with a 4-2-2 dB staircase strategy, similar to full threshold, and then with the method of constant stimuli (MOCS). Accuracy (threshold estimation error) was quantified by determination of differences between "true" threshold measurements made by MOCS and single staircase threshold estimates. Precision (repeatability) was quantified by the differences between repeated staircase threshold estimates. RESULTS: Precision was relatively high for both tests, although higher for FDP than SAP at depressed sensitivity levels. The staircase strategy significantly underestimated threshold sensitivity for both test types, with the mean difference (95% CI) between staircase and MOCS thresholds being 4.48 dB (2.35 to 7.32) and 1.35 dB (0.56 to 1.73) for SAP and FDP respectively. Agreement levels (weighted kappa) between MOCS and staircase thresholds were found to be 0.48 for SAP and 0.85 for FDP. Although this "bias" appeared constant for FDP across all sensitivity levels, this was not the case for SAP where accuracy decreased at lower sensitivity levels. CONCLUSION: Estimations of threshold sensitivity made using staircase strategies common to clinical visual field test instrumentation are associated with varying degrees of measurement error according to visual field test type and sensitivity. In particular, SAP significantly overestimates the "true" level of sensitivity, particularly in damaged areas of the visual field, suggesting that clinical data of this type should be interpreted with caution.
机译:目的:专为临床视野测试而设计的心理物理策略能够以相对较少的刺激提示快速估算阈值,因此代表了测试质量与效率之间的权衡。这项研究的目的是确定青光眼患者类似于标准自动视野检查(SAP)和倍频视野检查(FDP)的全阈值的阶梯算法的测量误差。方法:前瞻性招募了7例早期开角型青光眼(OAG)患者。所有人都具有基于实验室的心理物理学经验。在每个受试者的任意选择的一只眼睛中,使用SAP(外部驱动的汉弗莱现场分析仪)和FDP(CRT)检查了三个匹配的测试位置。使用4-2-2 dB阶梯策略(类似于全阈值)然后使用恒定刺激(MOCS)方法对每个位置进行两次测试。通过确定由MOCS进行的“真实”阈值测量与单个阶梯阈值估计之间的差异来量化准确性(阈值估计误差)。通过重复的阶梯阈值估计之间的差异来量化精度(可重复性)。结果:两种测试的精度均相对较高,尽管在灵敏度降低的情况下,FDP的精度高于SAP。阶梯策略显着低估了两种测试类型的阈值灵敏度,阶梯阈值和MOCS阈值之间的平均差(95%CI)对于SAP和FDP分别为4.48 dB(2.35至7.32)和1.35 dB(0.56至1.73)。发现MOCS和阶梯阈值之间的协议级别(加权kappa)对于SAP为0.48,对于FDP为0.85。尽管对于所有敏感度级别的FDP,此“偏差”似乎都是恒定的,但对于SAP,情况并非如此,在较低的敏感度级别上,准确性下降。结论:根据视野测试类型和灵敏度,使用临床视野测试仪器常用的阶梯策略进行阈值灵敏度估计与不同程度的测量误差相关。特别是,SAP明显高估了灵敏度的“真实”水平,尤其是在视野受损的区域,这提示应谨慎解释此类临床数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号