The effect of graphite precipitation and metal penetration have been discussed by many authors and much work has been made in the foundries to understand how to avoid metal penetration. Most of the grey-iron foundries around the world haveproblems with metal penetration on applicable components.The metal penetration in this work has been studied by thermo-analysis of casting experiments and metallographic observation of the microstructure coupled to the degree of penetration. The influence of the solidification path and time when it occurs, have been measured by using a standard thermo-analysis cup, modified with a sand core to facilitate a place for metal penetration. An open thermocouple was placed in the shell-core to detect the time of penetration.Ten different inoculants, representing five different groups of inoculants were investigated. The experiments show two main classes of eutectic cell sizes. One class nucleated at the beginning of the eutectic solidification and one at the end of thesolidification.The worst cases of metal penetration were obtained when the melt was not inoculated. A large number of small eutectic cells, and a high volume of the small cells were observed, which leads to large penetrations.The ferro-silicon-strontium inoculant was observed to give a high tendency to metal penetration. The ferro-silicon-zirconium-manganese inoculants showed a high nucleation rate at the end of the solidification and the average volume fraction of smalleutectic cells was high. The degree of penetration was in the medium range. The inoculant ferro-silicon-barium gave the best results with no or only small penetration. The ferro-silicon-titanium inoculant also showed a high nucleation rate at the end ofthe solidification, and the average volume fraction of small eutectic cells was high. The degree of penetration was in the medium range. The ferro-silicon-manganese inoculant showed little penetration.A high cooling rate gave severe penetration and the eutectic cell size was as expected small.At somewhat lower cooling rates in the thermal analysis cup, no penetration was observed in either the uninoculated or inoculated experiments.
机译:许多作者已经讨论了石墨沉淀和金属渗透的影响,并且在铸造厂进行了大量工作以了解如何避免金属渗透。世界上大多数灰铁铸造厂在适用部件上都有金属渗透的问题。这项工作中的金属渗透已通过铸造实验的热分析以及金相组织的显微观察与渗透程度进行了研究。凝固路径和凝固时间的影响已通过使用标准的热分析杯进行了测量,该杯采用砂芯修饰,以便于金属渗透。在壳核中放置一个开放式热电偶以检测渗透时间。研究了十种不同的孕育剂,它们代表五组不同的孕育剂。实验显示了两大类共晶细胞大小。一类在共晶凝固开始时成核,而一类在凝固结束时成核。当不接种熔体时,金属渗透的情况最差。观察到大量的小共晶细胞和大量的小细胞,从而导致大的渗透率。观察到铁硅锶锶孕育剂具有很高的金属渗透趋势。硅铁锆锰锰孕育剂在凝固结束时显示出高的成核率,并且小共晶细胞的平均体积分数很高。渗透程度在中等范围内。孕育硅铁钡剂的渗透效果最好,没有或只有很小的渗透率。硅铁钛孕育剂在凝固结束时也显示出高的成核率,并且小的共晶细胞的平均体积分数很高。渗透程度在中等范围内。硅铁锰孕育剂渗透率低,高冷却速率可导致严重渗透,低共熔孔尺寸如预期的那样小。在热分析杯中冷却速率稍低的情况下,未接种或接种的实验均未观察到渗透。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号