首页> 外文期刊>International angiology: A journal of the International Union of Angiology >Comparison of near-infrared spectroscopy with air plethysmography in detection of deep vein thrombosis.
【24h】

Comparison of near-infrared spectroscopy with air plethysmography in detection of deep vein thrombosis.

机译:近红外光谱与空气体积描记法在深静脉血栓形成检测中的比较。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

BACKGROUND: As a noninvasive screening test, air plethysmography (APG) is a reliable and frequently used modality in the detection of deep vein thrombosis (DVT). Although APG is highly sensitive for the diagnosis of proximal DVT, its sensitivity for identifying calf DVT is poor. Near-infrared spectroscopy (NIRS) is a new modality which can be used to evaluate venous retention during walking. The purpose of this study was to investigate the diagnostic value of NIRS for the detection of DVT, particularly isolated calf DVT, in comparison with APG. METHODS: Fifty limbs of 39 consecutive patients with clinically suspected DVT were studied. All patients were examined by venography and APG. Patients also underwent a treadmill-walking test with simultaneous NIRS. Deoxygenated hemoglobin was continuously measured by NIRS during exercise. The ambulatory venous retention index obtained from serial DeoHb changes was calculated in each patient. RESULTS: Venography demonstrated DVT in 35 limbs, confined to the calf in 9 limbs, and with the involvement of a proximal deep vein with thrombi in 26. The overall sensitivity of NIRS and APG was 97% (34/35) and 80% (28/35), respectively. NIRS was more sensitive than APG for detecting isolated calf DVT (89% [8/9] and 22% [2/9], respectively), while both tests identified proximal DVT in all limbs. CONCLUSIONS: NIRS is a highly sensitive method for the diagnosis of haemodynamically significant DVT. NIRS may become a useful screening test because of its reliability in detecting calf vein thrombi that cannot be identified by APG.
机译:背景:空气体积描记术(APG)作为一种非侵入性筛查测试,是检测深静脉血栓形成(DVT)的可靠且经常使用的方法。尽管APG对近端DVT的诊断高度敏感,但其对小腿DVT的识别敏感性却很差。近红外光谱(NIRS)是一种新的方式,可用于评估步行过程中的静脉滞留情况。这项研究的目的是研究与APG相比,NIRS对DVT(特别是小牛DVT)检测的诊断价值。方法:对39例临床怀疑为DVT的连续患者的50条肢体进行了研究。所有患者均接受静脉造影和APG检查。患者还接受了同时进行NIRS的跑步机行走测试。在运动过程中通过NIRS连续测量脱氧血红蛋白。从每位患者的DeoHb连续变化中得出动态静脉保留指数。结果:静脉造影显示DVT在35个肢体中局限于9个肢体的小腿内,并伴有近端深静脉伴有血栓的26个。NIRS和APG的总体敏感性分别为97%(34/35)和80%( 28/35)。对于检测孤立的小腿DVT(分别为89%[8/9]和22%[2/9]),NIRS比APG更为灵敏,而这两项测试均确定了所有肢体的DVT。结论:NIRS是诊断血液动力学显着DVT的高度灵敏的方法。由于NIRS可检测APG无法识别的小腿静脉血栓,因此它可能成为有用的筛查测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号