首页> 外文期刊>Atmospheric Measurement Techniques >Comparison of profile total ozone from SBUV (v8.6) with GOME-type and ground-based total ozone for a 16-year period (1996 to 2011)
【24h】

Comparison of profile total ozone from SBUV (v8.6) with GOME-type and ground-based total ozone for a 16-year period (1996 to 2011)

机译:比较了SBUV(v8.6)与GOME型和地面基总臭氧在16年内(1996年至2011年)的剖面臭氧总量

获取原文
获取原文并翻译 | 示例
       

摘要

This paper describes the comparison of the variability of total column ozone inferred from the three independent multi-year data records, namely, (i) Solar Backscatter Ultraviolet Instrument (SBUV) v8.6 profile total ozone, (ii) GTO (GOME-type total ozone), and (iii) ground-based total ozone data records covering the 16-year overlap period (March 1996 through June 2011). Analyses are conducted based on area-weighted zonal means for 0-30° S, 0-30° N, 50-30° S, and 30-60° N. It has been found that, on average, the differences in monthly zonal mean total ozone vary between -0.3 and 0.8 % and are well within 1 %. For GTO minus SBUV, the standard deviations and ranges (maximum minus minimum) of the differences regarding monthly zonal mean total ozone vary between 0.6-0.7 % and 2.8-3.8 % respectively, depending on the latitude band. The corresponding standard deviations and ranges regarding the differences in monthly zonal mean anomalies show values between 0.4-0.6 % and 2.2-3.5%. The standard deviations and ranges of the differences ground-based minus SBUV regarding both monthly zonal means and anomalies are larger by a factor of 1.4-2.9 in comparison to GTO minus SBUV. The ground-based zonal means demonstrate larger scattering of monthly data compared to satellite-based records. The differences in the scattering are significantly reduced if seasonal zonal averages are analyzed. The trends of the differences GTO minus SBUV and ground-based minus SBUV are found to vary between -0.04 and 0.1% yr~(-1) (-0.1 and 0.3 DU yr~(-1)). These negligibly small trends have provided strong evidence that there are no significant time-dependent differences among these multiyear total ozone data records. Analyses of the annual deviations from pre-1980 level indicate that, for the 15-year period of 1996 to 2010, all three data records show a gradual increase at 30-60° N from -5 % in 1996 to -2 % in 2010. In contrast, at 50-30° S and 30° S-30° N there has been a levelling off in the 15 years after 1996. The deviations inferred from GTO and SBUV show agreement within 1 %, but a slight increase has been found in the differences during the period 1996-2010.
机译:本文描述了从三个独立的多年数据记录推断出的总柱状臭氧变化的比较,这些记录是:(i)太阳背散射紫外线仪(SBUV)v8.6剖面总臭氧量;(ii)GTO(GOME型总臭氧),以及(iii)覆盖16年重叠期(1996年3月至2011年6月)的地面臭氧总数据记录。根据面积加权的纬度均值,对0-30°S,0-30°N,50-30°S和30-60°N进行平均。已经发现,平均而言,每月纬向差异平均臭氧总量在-0.3%至0.8%之间,并且在1%之内。对于GTO减去SBUV,月度纬向平均臭氧总量的差异的标准偏差和差异范围(最大减去最小值)分别在0.6-0.7%和2.8-3.8%之间,具体取决于纬度带。关于月度纬向平均距平差的相应标准偏差和范围显示在0.4-0.6%和2.2-3.5%之间的值。与GTO减去SBUV相比,月度纬向平均值和异常的地面减去SBUV的标准偏差和标准范围要大1.4-2.9倍。与基于卫星的记录相比,基于地面的分区方法显示每月数据的分散性更大。如果分析季节性纬向平均数,则散射差异将大大减少。发现GTO负SBUV和地面负SBUV的差异趋势在-0.04和0.1%yr〜(-1)之间变化(-0.1和0.3 DU yr〜(-1))。这些微不足道的小趋势提供了有力的证据,表明这些多年的臭氧总量记录之间没有显着的时间相关差异。对1980年以前水平的年度偏差的分析表明,在1996年至2010年的15年中,所有三个数据记录都显示在30-60°N处从1996年的-5%逐渐增加到2010年的-2%相比之下,在1996年之后的15年中,在北纬30-30°和北纬30°至30°N处趋于平稳。从GTO和SBUV得出的偏差显示在1%以内,但略有增加。发现在1996年至2010年期间的差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号