Two simple,rapid,accurate and precise spectrophotometric methods have been developed for simultaneous estimation of hydrochlorthi-azide and valsartan from tablet dosage form.Method I involves,formation of Q-absorbance equation at 264 nm (isoabsorptive point) and 270.5 (lambda_(max) of hydrochlorthiazide);while method II multicomponent mode of analysis involves the measurement of absorbances at two wavelengths 270.5 (lambda_(max) of hydrochlorthiazide) and 248.5 (lambda_(max) of valsartan) in methanol.The linearity lies between 2-30 mu g/mL for hydrochlorthiazide and 2-80 mu g/mL for valsartan,respectively.The accuracy and precision of the method was determined and validated statistically.The method showed good reproducibility and recovery with RSD % less than 1.The method was found to be rapid,economical,specific,precise and accurate and can be successfully applied for the routine analysis of hydrochlorthiazide and valsartan in bulk and combined dosage form.
机译:开发了两种简单,快速,准确和精确的分光光度法,用于从片剂剂型中同时估算盐酸噻嗪和缬沙坦。方法I涉及在264 nm(等吸收点)和270.5(lambda_(max );而方法II的多组分分析模式涉及在甲醇中的两个波长270.5(盐酸氢噻嗪的λ(max)和缬沙坦的λ(max))的吸光度的测量。线性在2-30 mu之间盐酸噻嗪的浓度为g / mL,缬沙坦为2-80μg/ mL,该方法的准确度和精密度经统计学确定和验证,该方法具有良好的重现性和回收率,RSD%小于1。快速,经济,特异性,精确和准确,可成功地用于散装和组合剂型中的盐酸噻嗪和缬沙坦的常规分析。