Objective: To assess the false-positive and false-negative rates of a 4th-generation human immunodeficiency virus (HIV) assay, the Abbott ARCHITECT, vs 2 HIV 3rd-generation assays, the Siemens Centaur and the Ortho-Clinical Diagnostics Vitros. Methods: We examined 123 patient specimens. In the first phase of the study, we compared 99 specimens that had a positive screening result via the 3rd-generation Vitros assay (10 positive, 82 negative, and 7 indeterminate via confirmatory immunofluorescent assay IFA/ Western blot WB testing). In the second phase, we assessed 24 HIV-1 RNA-positive (positive result via the nuclear acid amplification test NAAT and negative/indeterminate results via the WB test) specimens harboring acute HIV infection. Results: The 4th-generation ARCHITECT assay yielded fewer false-positive results (n = 2) than the 3rd-generation Centaur (n = 9: P = .02) and Vitros (n = 82; P<.001) assays. One confirmed positive case had a false-negative result via the Centaur assay. When specimens from the 24 patients with acute HIV-1 infection were tested, the ARCHITECT assay yielded fewer false-negative results (n = 5) than the Centaur (n = 10) (P = .13) and the other 3rd-generation tests (n = 16) (P= .002). Conclusions: This study indicates that the 4th-generation ARCHITECT HIV assay yields fewer false-positive and false-negative results than the 3rd-generation HIV assays we tested.
机译:目的:评估第四代人类免疫缺陷病毒 (HIV) 检测 Abbott ARCHITECT 与 2 种第三代 HIV 检测、Siemens Centaur 和 Ortho-Clinical Diagnostics Vitros 的假阳性率和假阴性率。方法:我们检查了 123 例患者标本。在研究的第一阶段,我们比较了 99 个通过第 3 代 Vitros 检测获得阳性筛查结果的标本(10 个阳性、82 个阴性和 7 个通过确认性免疫荧光测定 [IFA]/蛋白质印迹 [WB] 检测不确定)。在第二阶段,我们评估了 24 个携带急性 HIV 感染的 HIV-1 RNA 阳性(通过核酸扩增试验 [NAAT] 呈阳性结果,通过 WB 检测呈阴性/不确定结果)。结果:第 4 代 ARCHITECT 检测产生的假阳性结果 (n = 2) 少于第 3 代 Centaur (n = 9: P = 0.02) 和 Vitros (n = 82;P<.001)测定。一例确诊的阳性病例通过半人马座检测得出假阴性结果。当对 24 名急性 HIV-1 感染患者的标本进行检测时,ARCHITECT 检测产生的假阴性结果 (n = 5) 少于半人马座 (n = 10) (P = .13) 和其他第三代检测 (n = 16) (P = .002)。结论:本研究表明,与我们测试的第三代 HIV 检测相比,第 4 代 ARCHITECT HIV 检测产生的假阳性和假阴性结果更少。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号