首页> 外文期刊>Angle Orthodontist >Comparisons of two approaches for removing excess adhesive during the bonding procedure.
【24h】

Comparisons of two approaches for removing excess adhesive during the bonding procedure.

机译:比较两种在粘合过程中去除多余粘合剂的方法。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The purpose of this study was to compare the effects on shear bond strength of removing excess adhesive from around the bracket base at 2 time periods: (1) immediately after placing the bracket on the tooth, and (2) after subjecting the adhesive to 5 seconds of light curing to initially secure the bracket in its proper position. The debonding forces were evaluated at 2 times; within half an hour after bonding and after storing for 24 hours in water at 37 degrees qC. These comparisons will help determine the most advantageous time for the clinician to remove excess adhesive from around the brackets during the bonding process. The teeth were randomly divided into 4 groups according to: (a) the time of removal of the excess adhesive from around the bracket base namely; immediately after placing the bracket or after 5 seconds of light cure and (b) the time of debonding the brackets, namely within half an hour or after 24 hours. Shear bond strength was measured using a Zwick test machine and calculated in Megapascals. The results of the analysis of variance (F = 35.05) comparing the 4 experimental groups indicated the presence of significant differences between all 4 groups (P = .0001). In general, the shear bond strengths were significantly larger for the 2 groups debonded after 24 hours, whether they were light cured for a total of 40 seconds (X = 8.8 +/- 3.6 MPa) or 45 seconds (X = 6.9 +/- 3.4 MPa). On the other hand, the shear bond strengths was significantly lower in the 2 groups debonded within half an hour from their initial bonding, whether light cured for 40 seconds (X = 0.4 +/- 1.0 MPa) or 45 seconds (X = 3.4 +/- 2.7 MPa). In conclusion, the additional 5 seconds of light cure significantly increased the initial shear bond strength. On the other hand, removing excess adhesive after 5 seconds of light cure significantly decreased the shear bond strength at 24 hours.
机译:这项研究的目的是比较在两个时间段内从托槽底座周围去除多余粘合剂对剪切粘结强度的影响:(1)将托槽放置在牙齿上后立即;(2)使粘合剂经受5次固化几秒钟即可将支架最初固定在正确的位置。剥离力评估为2次。粘接后半小时内,以及在37度qC的水中存放24小时后。这些比较将有助于确定临床医生在粘合过程中从支架周围去除多余粘合剂的最有利时间。根据以下内容将牙齿随机分为4组:(a)从支架基部周围去除多余粘合剂的时间,即;放置支架后立即进行固化或在5秒钟的光固化后立即进行;(b)剥离支架的时间,即半小时内或24小时后。剪切粘合强度使用Zwick测试机测量并以兆帕斯卡计算。比较4个实验组的方差分析结果(F = 35.05)表明,所有4个组之间均存在显着差异(P = .0001)。通常,无论是光固化总共40秒(X = 8.8 +/- 3.6 MPa)还是45秒(X = 6.9 +/-),它们在24小时后解粘的两组的剪切粘结强度都明显更高。 3.4 MPa)。另一方面,无论是光固化40秒(X = 0.4 +/- 1.0 MPa)还是45秒(X = 3.4 + /-2.7 MPa)。总之,额外的5秒钟光固化会显着提高初始剪切粘结强度。另一方面,在光固化5秒后去除多余的粘合剂会显着降低24小时的剪切粘合强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号