首页> 外文期刊>Analytical methods >Self-assembly pipette tip-based cigarette filters for micro-solid phase extraction of ketoconazole cis-enantiomers in urine samples followed by high-performance liquid chromatography/diode array detection
【24h】

Self-assembly pipette tip-based cigarette filters for micro-solid phase extraction of ketoconazole cis-enantiomers in urine samples followed by high-performance liquid chromatography/diode array detection

机译:自组装基于移液器吸头的香烟过滤嘴,用于微固相萃取尿液样品中的酮康唑顺式对映体,然后进行高效液相色谱/二极管阵列检测

获取原文
获取原文并翻译 | 示例
           

摘要

A simple stereoselective HPLC/DAD method was developed for the determination of ketoconazole (KTZ) cis-enantiomers in human urine. In addition, the potential use of pipette tip-based cigarette filters for micro-solid phase extraction (PT-CFs-m-SPE) of KTZ cis-enantiomers in human urine samples prior to HPLC/DAD was studied in this paper. In order to find a suitable procedure for extraction of KTZ cis-enantiomers in human urine, various parameters that probably affect the extraction efficiency including the washing solvent, eluent kind and volume, pH, quantity of the material, sample volume and ionic strength were systematically optimized. Optimum chromatographic separations among the KTZ cis-enantiomers have been achieved within 10 minutes using a Chiralpak (R) IA column (100 x 4.6 mm, 3 mm) as the stationary phase with a mobile phase consisting of 100% ethanol at a flow rate of 1 mL min(-1). Detection was performed at 250 nm. The performance criteria for linearity, sensitivity, precision, accuracy, recovery, robustness and stability have been assessed and were within the recommended guidelines. The mean extraction recoveries/relative standard deviation for (+)-(2R, 4S)-KTZ and (-)-(2S, 4R)-KTZ were 100.74 +/- 9.52% and 106.90 +/- 9.26%, respectively. The method showed to be linear over the concentration range of 12.5 to 400 ng mL(-1) for each enantiomer with the correlation coefficients of 0.9946 and 0.9910, for (+)-(2R, 4S)-KTZ and (-)-(2S, 4R)-KTZ, respectively. Within-day and between-day precision and accuracy assays for these analytes were studied at three concentration levels and were lower than 15%. The method was successfully employed in a preliminary cumulative urinary excretion study after administration of racemic cis-KTZ to a healthy volunteer.
机译:开发了一种简单的立体选择性HPLC / DAD方法,用于测定人尿中的酮康唑(KTZ)顺式对映异构体。此外,本文还研究了基于移液器吸头的香烟过滤嘴在HPLC / DAD之前用于尿液样品中KTZ顺式对映异构体的微固相萃取(PT-CFs-m-SPE)的潜在用途。为了找到合适的提取人尿液中KTZ顺式对映体的方法,系统地影响了可能影响提取效率的各种参数,包括洗涤溶剂,洗脱液的种类和体积,pH值,材料的数量,样品的体积和离子强度。优化。使用Chiralpak IA色谱柱(100 x 4.6 mm,3 mm)作为固定相,流动相由100%乙醇组成的流动相,在10分钟内可实现KTZ顺式对映异构体之间的最佳色谱分离1 mL min(-1)。在250nm处进行检测。评估了线性,灵敏度,精密度,准确性,回收率,鲁棒性和稳定性的性能标准,并在推荐的准则之内。 (+)-(2R,4S)-KTZ和(-)-(2S,4R)-KTZ的平均萃取回收率/相对标准偏差分别为100.74 +/- 9.52%和106.90 +/- 9.26%。对于(+)-(2R,4S)-KTZ和(-)-(),该方法在每种对映异构体的浓度范围为12.5至400 ng mL(-1)时呈线性关系,相关系数为0.9946和0.9910。 2S,4R)-KTZ。这些分析物的日内和日间精密度和准确度分析是在三种浓度水平下进行的,并且低于15%。向健康志愿者服用外消旋顺式-KTZ后,该方法成功用于初步的累积尿排泄研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号