首页> 外文期刊>IOSR journal of mechanical and civil engineering >Mathematical Models for Predicting Maximum Cooling Load ofAC Vapour CompressionMilkSolar Refrigeration Systems
【24h】

Mathematical Models for Predicting Maximum Cooling Load ofAC Vapour CompressionMilkSolar Refrigeration Systems

机译:用于预测最大冷却载荷的数学模型蒸汽压缩型制冷系统的最大冷却载荷

获取原文
获取原文并翻译 | 示例
           

摘要

The mismatch between solar energy availability and the cooling load energy demands for AC solar refrigeration systems in different geographical locations complicates the design and sizing of milk solar refrigeration systems components. This is caused by variation seasonal solar insolation and different levels of global solar insolation. In this study, three different sizes AC milk solar refrigeration systems, have been investigated for maximum cooling loads developed from the refrigeration systems when exposed to varying levels of solar insolation in Nakuru Kenya. Regression models were developed for predicting maximum cooling loads delivered from the milk solar refrigeration systems based on available mean daily solar insolation of the location. The predictive models developed is useful tools in the design and sizing of milk solar refrigeration components based on solar insolation available at any global location. Three Solar refrigeration systems were fitted with AC reciprocating compressors of capacities'; 350W, 250W, 200W and were investigated for maximum cooling loads under varying mean daily solar insolation. Four PV panels each of 200 Wp connected via an inverter provided the power required to operate the compressors in each of the refrigeration system. An innovative control unit operated the refrigeration systems dependent on the solar insolation level available in the day. Temperature profiles of water placed in the centrahvater can, and the amount of ice formed were used to determine the maximum cooling load of each refrigeration system with, based on solar radiation available. The regression cooling curve generated by each system was used in developing the mathematical cooling load prediction models based on available solar insolation of Nakuru Conclusion: The results showed that the maximum cooling loads obtained from the solar refrigeration systemsis dependent on the annual mean daily solar insolation of a specific location and the capacity of the refrigeration system compressor. The mathematical models showed a strong correction of coefficient of between 0.958 and 0.908 when validated with actual solar refrigeration cooling loads.
机译:None

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号