Sampling of organophosphorus pesticides at trace levels in the atmosphere using XAD-2 adsorbent and analysis by gas chromatography coupled with nitrogen-phosphorus and ion-trap mass spectrometry detectors

机译:使用XAD-2吸附剂在大气中对痕量有机磷农药进行采样,并通过气相色谱法与氮磷和离子阱质谱检测器结合进行分析

获取原文
获取原文并翻译 | 示例
           

摘要

This paper shows an analytical methodology based on solid-phase extraction by XAD-2 adsorbent and gas chromatography (GC) coupled with nitrogen-phosphorus (NPD) and ion-trap mass spectrometry detectors (ITMS) in negative chemical ionization (NCI) mode analyses for investigating organophosphorus pesticides (OPs) at trace levels (in nanograms per cubic meter) in the atmosphere: in particular, we set up a procedure for analyzing 38 OPs. For the analytical methodology linearity responses have been obtained in GC-NPD (r>0.9982) and GC-NCI/ITMS (r>0.9974) in a large linearity range (0.10-500 pg μL ~(-1) in both cases) whereas the limits of detection range between 0.01 and 0.03 pg μL ~(-1) in both the techniques with a relative standard deviation (RSD) below 9.0 in both cases. Particular attention has been devoted to investigate the effect of different solvents (n-hexane, benzene, chloroform, carbon disulfide, acetonitrile) on the OP recovery as well the breakthrough volumes have been evaluated (100 % recovery up to 4,286 Lg ~(-1)). The study has also investigated the OP recoveries at different sampling flow rates (1.5 and 2.0 L min ~(-1)) for determining the optimal conditions for sample collection. Finally, the whole approach has been successfully applied to real samples collected in four different areas in the Molise region (Central Italy) during different seasons: the results show that parathion-ethyl, dimethoate, omethoate, and malathion are present in all periods at low levels (ranging between 70 and 10 ng m ~(-3)): their levels in such periods can be correlated with spraying as well atmospheric conditions favoring the dispersion/accumulation of these pollutants
机译:本文展示了一种基于XAD-2吸附剂固相萃取,气相色谱(GC)结合氮磷(NPD)和离子阱质谱检测器(ITMS)进行负化学电离(NCI)模式分析的分析方法用于研究大气中痕量水平(以纳克每立方米为单位)的有机磷农药:特别是,我们建立了分析38种OP的程序。对于分析方法,已在较大的线性范围内(两种情况下均为0.10-500 pgμL〜(-1))在GC-NPD(r> 0.9982)和GC-NCI / ITMS(r> 0.9974)中获得了线性响应。两种技术中的检测范围限制在0.01和0.03 pgμL〜(-1)之间,两种情况下的相对标准偏差(RSD)均低于9.0。已特别关注研究不同溶剂(正己烷,苯,氯仿,二硫化碳,乙腈)对OP回收率的影响,并评估了突破体积(100%回收率高达4,286 Lg〜(-1) ))。该研究还研究了在不同采样流速(1.5和2.0 L min〜(-1))下的OP回收率,以确定样品收集的最佳条件。最后,整个方法已成功应用于不同季节在莫利塞地区(意大利中部)四个不同地区收集的真实样品:结果表明,对硫磷-乙基,乐果,氧化乐果和马拉硫磷在各个时期均处于低水平浓度(范围在70到10 ng m〜(-3)之间):在此期间它们的浓度可以与喷雾以及有利于这些污染物的分散/积累的大气条件相关

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号