An electrospray ionization tandem mass spectrometric (ESI-MS-MS) method has been developed for the determination of cyanide (CN~-) in blood. Five microliters of blood was hemolyzed with 50 μL of water, then 5 μL of 1 M tetramethylammonium hydroxide solution was added to raise the pH of the hemolysate and to liberate CN~- from methemoglobin. CN~- was then reacted with NaAuCl_4 to produce dicyanogold, Au(CN) _2~-, that was extracted with 75 μL of methyl isobutyl ketone. Ten microliters of the extract was injected directly into an ESI-MS-MS instrument and quantification of CN~- was performed by selected reaction monitoring of the product ion CN~- at m/z 26, derived from the precursor ion Au(CN) _2~- at m/z 249. CN~- could be measured in the quantification range of 2.60 to 260 μg/L with the limit of detection at 0.56 μg/L in blood. This method was applied to the analysis of clinical samples and the concentrations of CN~- in the blood were as follows: 7.13∈±∈2.41 μg/L for six healthy non-smokers, 3.08∈±∈1.12 μg/L for six CO gas victims, 730∈±∈867 μg for 21 house fire victims, and 3,030∈±∈97 μg/L for a victim who ingested NaCN. The increase of CN~- in the blood of a victim who ingested NaN_3 was confirmed using MS-MS for the first time, and the concentrations of CN - in the blood, gastric content and urine were 78. 5∈±∈5.5, 11.8∈±∈0.5, and 11. 4∈±∈0.8 μg/L, respectively.
机译:已经开发出一种电喷雾电离串联质谱法(ESI-MS-MS),用于测定血液中的氰化物(CN〜-)。用50μL的水将5微升的血液溶血,然后加入5μL的1 M氢氧化四甲铵溶液以提高溶血液的pH值,并从高铁血红蛋白中释放出CN-。然后使CN〜-与NaAuCl_4反应生成二氰基金Au(CN)_2〜-,将其用75μL甲基异丁基酮萃取。将十微升提取物直接注入ESI-MS-MS仪器中,并通过对源自前体离子Au(CN)的产物离子CN--在m / z 26处的选定反应监测进行选择,对CN-进行定量。 _2〜-在m / z249。CN〜-可以在2.60至260μg/ L的定量范围内测量,血液中的检出限为0.56μg/ L。该方法用于临床样本分析,血液中CN〜-的浓度为:六个健康非吸烟者为7.13∈±ε2.41μg/ L,六个CO为3.08∈±ε1.12μg/ L。气体受害者,其中21位房屋火灾受害者为730∈±∈867μg,摄入NaCN的受害者为3030∈±∈97μg/ L。首次使用MS-MS确认了摄入NaN_3的受害者血液中CN〜-的升高,并且血液,胃内容物和尿液中CN-的浓度为78。5∈±∈5.5,11.8 ∈±∈0.5和11.4∈±∈0.8μg/ L。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号