首页> 外文期刊>Analytical chemistry >Rapid, specific determination of iodine and iodide by combined solid-phase extraction/diffuse reflectance spectroscopy
【24h】

Rapid, specific determination of iodine and iodide by combined solid-phase extraction/diffuse reflectance spectroscopy

机译:固相萃取/漫反射光谱相结合的方法快速,特异性地测定碘和碘化物

获取原文
获取原文并翻译 | 示例
       

摘要

A new, rapid methodology for trace analysis using solid-phase extraction is described. The two-step methodology is based on the concentration of an analyte onto a membrane disk and on the determination by diffuse reflectance spectroscopy of the amount of analyte extracted on the disk surface. This method, which is adaptable to a wide range of analytes, has been used for monitoring ppm levels of iodine and iodide in spacecraft water. Iodine is used as a biocide in spacecraft water. For these determinations, a water sample is passed through a membrane disk by means of a 10-mL syringe that is attached to a disk holder assembly. The disk, which is a polystyrene- divinylbenzene composite, is impregnated with poly(vinylpyrrolidone) (PVP), which exhaustively concentrates iodine as a yellow iodine-PVP complex. The amount of concentrated iodine is then determined in only 2 s by using a hand-held diffuse reflectance spectrometer by comparing the result with a calibration curve based on the Kubelka-Munk function. The same general procedure can be used to determine iodide levels after its facile and exhaustive oxidation to iodine by peroxymonosulfate (i.e., Oxone reagent). For samples containing both analytes, a two-step procedure can be used in which the iodide concentration is calculated from the difference in iodine levels before and after treatment of the sample with peroxymonosulfate. With this methodology, iodine and iodide levels in the 0.1-5.0 ppm range can be determined with a total workup time of similar to60 s with a RSD of similar to6%. [References: 17]
机译:描述了一种使用固相萃取进行痕量分析的新的快速方法。两步方法基于膜盘上分析物的浓度以及通过漫反射光谱法确定在盘表面上提取的分析物的量。该方法适用于多种分析物,已用于监测航天器水中的ppm碘和碘化物含量。碘在航天器水中用作杀菌剂。为了进行这些测定,水样品通过一个10毫升注射器(通过一个固定在磁盘支架组件上的注射器)通过膜片磁盘。圆盘是聚苯乙烯-二乙烯基苯复合物,浸有聚(乙烯基吡咯烷酮)(PVP),可将碘完全浓缩为黄色碘-PVP复合物。然后,使用手持式漫反射光谱仪,通过将结果与基于Kubelka-Munk函数的校准曲线进行比较,只需2秒钟即可确定浓碘的量。在过氧一硫酸盐(即Oxone试剂)将碘化物容易且彻底氧化为碘之后,可以使用相同的通用程序确定碘化物的水平。对于包含两种分析物的样品,可以使用两步程序,其中碘离子浓度是根据过氧一硫酸盐处理样品前后的碘含量差异计算得出的。使用这种方法,可以在总处理时间约为60 s,RSD约为6%的情况下确定0.1-5.0 ppm范围内的碘和碘化物水平。 [参考:17]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号