The development of new methods and improvements of existing methods for the specific activity determination of Sr-90 and other distinct beta emitters has been of considerable interest. The reason for this interest is that the notably small number of methods that are able to meet all the set criteria, such as reliability of the results, measurement uncertainty and time, and minimum production of radioactive waste, as well as applicability to various samples with reference to their nature, geometry and composition. In this paper, two methods for rapid Sr-90 activity determination based on Monte Carlo simulations are used, one for a Si semiconductor detector for beta spectrometric measurements and the other for the Geiger-Muller (GM) ionization probe. To improve the reliability of the measurement results, samples with high and low strontium activity solutions were prepared in the form of dry residues. The results of the proposed methodology were verified with a standard method using a liquid scintillation counter, and notably good agreements are achieved.
机译:新方法和改进现有方法的特定活性测定SR-90和其他明显的β发射者的方法具有相当大的兴趣。对此兴趣的原因是,能够满足所有设定标准的明显少量方法,例如结果的可靠性,测量不确定性和时间,以及放射性废物的最低生产,以及适用于各种样品参考他们的性质,几何和组成。在本文中,使用了基于蒙特卡罗模拟的SR-90活性测定的两种方法,用于Si半导体检测器,用于β光谱测量值,另一个用于Geiger-Muller(GM)电离探针。为了提高测量结果的可靠性,以干燥残余物的形式制备具有高和低锶活性溶液的样品。用液体闪烁计数器的标准方法验证了所提出的方法的结果,并且达到了良好的协议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号