In the paper, there are presented the calculation results of eigenvalues associated with electromechanical phenomena (i.e. electromechanical eigenvalues) of the power system (PS) model state matrix based on the analysis of instantaneous power disturbance waveforms. The method used for calculations does not require determining the PS (linearized in the operating point) state matrix of large dimensions. The disturbances taken into account in the investigations are: pulse or step changes (with a small amplitude) in the voltage regulator reference voltage in one of generating units, a symmetrical short-circuit in a transmission line and a change in the value of the PS line equivalent impedance (due to, e.g., disconnecting or connecting a large power load). In the PS model, there was taken into account the impact of a central frequency regulator. The presented method for calculations of eigenvalues consists of approximation of the instantaneous power waveforms by the super-position of modal components associated with the searched eigenvalues. This approximation can be performed by minimization of the objective function defined as a mean square error between the approximated and approximating waveform. The hybrid optimization algorithm, being a serial combination of genetic and gradient algorithms, was used for minimization of the so-defined objective function. Such a combination allows eliminating the main disadvantages of both component algorithms. In order to avoid calculation errors caused by the algorithm freezing in an objective function local minimum, the calculations of eigenvalues were carried out repeatedly for each disturbance waveform. The calculation results with the objective function values larger than the assumed limit value were rejected. The arithmetic means from the non-rejected calculation results were assumed to be the final calculation results of the real and imaginary parts of particular eigenvalues. (C) 2017 Elsevier Inc. All rights reserved.
机译:本文基于瞬时电力干扰波形的分析,介绍了与电力系统(PS)模型矩阵的机电现象(即机电特征值)相关的特征值的计算结果。用于计算的方法不需要确定大尺寸的PS(在操作点中的线性化)状态矩阵。在调查中考虑的干扰是:脉冲或步骤在发电机单元之一中的电压调节器参考电压中的脉冲或步骤变化(具有小幅度),在传输线中的对称短路和PS值的变化线等效阻抗(由于例如断开或连接大功率负载)。在PS模型中,考虑了中央频率调节器的影响。呈现的特征值的计算方法包括通过与搜索的特征值相关联的模态分量的超时的瞬时功率波形的近似。可以通过最小化定义为近似波形和近似波形之间的平均误差的目标函数来执行该近似。混合优化算法是遗传和梯度算法的串行组合,用于最小化所定义的目标函数。这种组合允许消除组件算法的主要缺点。为了避免由目标函数局部最小冻结算法引起的计算误差,针对每个干扰波形重复进行特征值的计算。计算结果具有比假定的极限值大的目标函数值被拒绝。假设来自非拒绝计算结果的算术装置是特定特征值的实部和虚部的最终计算结果。 (c)2017年Elsevier Inc.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号