...
首页> 外文期刊>Analytical and bioanalytical chemistry >Development of an LC-MS/MS method for the detection of traces of peanut allergens in chili pepper
【24h】

Development of an LC-MS/MS method for the detection of traces of peanut allergens in chili pepper

机译:开发LC-MS / MS方法,用于检测辣椒痕的花生过敏原

获取原文
获取原文并翻译 | 示例

摘要

The recent detection of nuts (including peanut) in spices across the globe has led to enormous recalls of several spices and food products in the last two years. The lack of validated detection methods specific for spices makes it difficult to assess allergen presence at trace levels. Because of the urgent need for confirmation of possible peanut presence in chili peppers, an LC-MS/MS method was optimized and developed for this particular food matrix. Although several studies optimized LC-MS detection strategies specific for peanuts, the presence of complex components in the spices (e.g., phenolic components) makes method optimization and validation necessarily. Focus was laid on validation of the method with real incurred chili peppers (whereby a known amount of peanut is added) at low concentrations, to deal with possible matrix interferences. LC-MS/MS proves to be a good alternative to the currently most applied methods (ELISA and RT-PCR) and can be used as a complementary method of analysis when results are unclear. Peanut marker peptides were selected based on their abundancy in digested incurred chili peppers. The limit of detection was determined to be 24 ppm (mg peanut/kg), a level whereby the risk for potential allergic reactions is zero, considering the typical portion size of spices. The chili pepper powder under investigation proved to contain low levels of peanuts after LC-MS/MS, ELISA, and RT-PCR testing.
机译:最近全球香料中的坚果(包括花生)的检测导致了过去两年中几种香料和食品的巨大回忆。缺乏对香料特异的验证检测方法使得难以在痕量水平下评估过敏原的存在。由于迫切需要在辣椒中确认可能的花生存在,针对该特定食物基质进行了优化和开发了LC-MS / MS方法。虽然几项研究优化了花生特异性LC-MS检测策略,但是在香料(例如,酚类组分)中存在复杂的组分,使方法优化和验证必然。重点是验证了实际发生的辣椒的方法(在低浓度下添加了已知量的花生),以处理可能的基质干扰。 LC-MS / MS证明是目前最多应用方法(ELISA和RT-PCR)的良好替代方案,当结果尚不清楚时,可以用作互补分析方法。基于它们在消化的辣椒中的丰度来选择花生标记肽。测定检测限为24ppm(mg花生/ kg),潜在过敏反应风险为零,考虑到香料的典型部分尺寸。在LC-MS / MS,ELISA和RT-PCR测试后,正在调查的辣椒粉被证明含有低水平的花生。

著录项

  • 来源
  • 作者单位

    Flanders Res Inst Inst Agr Fisheries &

    Food ILVO Technol &

    Food Sci Unit Burg Van Gansberghelaan 115 B-9820 Merelbeke Belgium;

    Flanders Res Inst Inst Agr Fisheries &

    Food ILVO Technol &

    Food Sci Unit Burg Van Gansberghelaan 115 B-9820 Merelbeke Belgium;

    Flanders Res Inst Inst Agr Fisheries &

    Food ILVO Technol &

    Food Sci Unit Burg Van Gansberghelaan 115 B-9820 Merelbeke Belgium;

    Flanders Res Inst Inst Agr Fisheries &

    Food ILVO Technol &

    Food Sci Unit Burg Van Gansberghelaan 115 B-9820 Merelbeke Belgium;

    Flanders Res Inst Inst Agr Fisheries &

    Food ILVO Technol &

    Food Sci Unit Burg Van Gansberghelaan 115 B-9820 Merelbeke Belgium;

    Univ Ghent Dept Otorhinolaryngol Fac Med &

    Hlth Sci B-9000 Ghent Belgium;

    Univ Ghent Fac Med &

    Hlth Sci Dept Dermatol B-9000 Ghent Belgium;

    Flanders Res Inst Agr Fisheries &

    Food ILVO Technol &

    Food Sci Unit Brusselsesteenweg 370 B-9090 Melle Belgium;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学 ;
  • 关键词

    Allergens; UHPLC-MS/MS method; Peanut in chili pepper; Incurred food matrices;

    机译:过敏原;UHPLC-MS / MS方法;花生在辣椒;发生的食物矩阵;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号