...
首页> 外文期刊>Analytical and bioanalytical chemistry >New sample preparation method based on task-specific ionic liquids for extraction and determination of copper in urine and wastewater
【24h】

New sample preparation method based on task-specific ionic liquids for extraction and determination of copper in urine and wastewater

机译:基于任务特异性离子液体的新型样品制备方法,用于尿液和废水中铜的提取和测定

获取原文
获取原文并翻译 | 示例
           

摘要

In this study, four hydrophilic ionic liquids (ILs) containing 1-alkyl-3-methylimidazolim cation and either salicylate or chloride anions were synthetized and studied as new task-specific ionic liquids (TSILs) suitable for aqueous biphasic system (ABS) formation and selective one-step extraction of copper(II). TSILs are designed so that the anion is responsible for forming the complex with metal(II) and preventing hydrolysis of metal cations at very strong alkaline pH, whereas the cation is responsible for selective extraction of metal(II)-salicylate complexes. It was found that 1-butyl-3-methylimidazolium salicylate could be used for selective extraction of Cu(II) in the presence of Zn(II), Cd(II), and Pb(II) at very alkaline solution without metal hydroxide formation. It was assumed that formation of metal(II)-salicylate complexes prevents the hydrolysis of the metal ions in alkaline solutions. The determined stability constants for Cu(II)-salicylate complexes, where salicylate was derived from different ionic liquids, indicated that there was no significant influence of the cation of the ionic liquid on the stability of the complexes. The ABS based on 1-butyl-3-methylimidazolium salicylate has been applied as the sample preparation step prior to voltammetric determination of Cu(II). The effect of volume of aqueous sample and IL and extraction time were investigated and optimum extraction conditions were determined. The obtained detection limits were 8 ng dm(-3). The optimized method was applied for the determination of Cu(II) in tap water, wastewater, and urine. The study indicated that application of the ABS based on 1-butyl-3-methylimidazolium salicylate ionic liquid could be successfully applied as the sample preparation method for the determination of Cu(II) from various environmental samples.
机译:在该研究中,合成了含有1-烷基-3-甲基咪唑米阳离子和水杨酸盐或氯离子的四种亲水离子液体(ILS),并作为适用于水性双相系统(ABS)形成的新任务特异性离子液体(TSIL)和选择性一步提取铜(II)。设计了TSILS,使阴离子负责与金属(II)形成复合物并防止金属阳离子在非常强的碱性pH下水解,而阳离子负责选择性提取金属(II) - 羟基酯络合物。结果发现,在没有金属氢氧化物形成的情况下,在Zn(II),CD(II)和Pb(II)的存在下,可用于在Zn(II),CD(II)和Pb(II)的情况下选择性提取1-丁基-3-甲基咪唑鎓盐,用于在没有金属氢氧化物形成的情况下。假设金属(II)的形成 - 仲晶酯配合物可防止金属离子在碱性溶液中的水解。用于Cu(II) - 羟基硅酸盐复合物的确定的稳定性常数,其中水杨酸酯衍生自不同的离子液体,表明离子液体阳离子对复合物的稳定性没有显着影响。基于1-丁基-3-甲基咪唑鎓水溶生的ABS已在伏安法测定Cu(II)之前应用于样品制备步骤。研究了水性样品和IL的体积和提取时间的影响,测定了最佳的提取条件。获得的检测限为8ng DM(-3)。应用优化的方法用于测定自来水,废水和尿液中的Cu(II)。该研究表明,基于1-丁基-3-甲基咪唑鎓水杨酸盐离子液体的ABS的施用可以成功地应用于测定来自各种环境样品的Cu(II)的样品制备方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号