首页> 外文期刊>Analytical chemistry >First-Principles Collision Cross Section Measurements of Large Proteins and Protein Complexes
【24h】

First-Principles Collision Cross Section Measurements of Large Proteins and Protein Complexes

机译:大型蛋白质和蛋白质复合物的第一原理碰撞横截面测量

获取原文
获取原文并翻译 | 示例
       

摘要

Rotationally averaged collision cross section (CCS) values for a series of proteins and protein complexes ranging in size from 8.6 to 810 kDa are reported. The CCSs were obtained using a native electrospray ionization drift tube ion mobility-Orbitrap mass spectrometer specifically designed to enhance sensitivity while having high-resolution ion mobility and mass capabilities. Periodic focusing (PF)-drift tube (DT)-ion mobility (IM) provides first-principles determination of the CCS of large biomolecules that can then be used as CCS calibrants. The experimental, first-principles CCS values are compared to previously reported experimentally determined and computationally calculated CCS using projected superposition approximation (PSA), the Ion Mobility Projection Approximation Calculation Tool (IMPACT), and Collidoscope. Experimental CCS values are generally in agreement with previously reported CCSs, with values falling within similar to 5.5%. In addition, an ion mobility resolution (CCS centroid divided by CCS fwhm) of similar to 60 is obtained for pyruvate kinase (MW similar to 233 kDa); however, ion mobility resolution for bovine serum albumin (MW similar to 68 kDa) is less than similar to 20, which arises from sample impurities and underscores the importance of sample quality. The high resolution afforded by the ion mobility-Orbitrap mass analyzer provides new opportunities to understand the intricate details of protein complexes such as the impact of post-translational modifications (PTMs), stoichiometry, and conformational changes induced by ligand binding.
机译:报道了一系列蛋白质和蛋白质复合物的旋转平均脉冲横截面(CCS)值,范围为8.6至810kDa。使用本机电离电离漂移管离子迁移率 - 轨道质谱仪获得CCSS,专门设计成增强灵敏度,同时具有高分辨率离子迁移率和质量能力。周期性聚焦(PF)-Drift管(DT)迁移率(IM)提供了一种主要方法可以用作CCS校准剂的大型生物分子的CCS的第一原理。将实验性的第一原理CCS值与先前报道的使用投影叠加近似(PSA)进行了实验确定和计算计算的CCS,离子迁移率投影近似计算工具(冲击)和侵占。实验性CCS值通常与先前报告的CCSS一致,价值观下降到类似于5.5%。此外,对于类似于60的离子迁移率分辨率(CCS质心除以CCS FWHM),用于丙酮酸激酶(MW类似于233kDa);然而,对牛血清白蛋白的离子迁移率分辨率(类似于68kDa)的离子迁移率分辨率小于样品杂质和强调样品质量的重要性。离子迁移率 - 轨道物质分析仪提供的高分辨率提供了了解蛋白质复合物的复杂细节,例如通过配体结合诱导的翻译后修饰(PTMS),化学计量和构象变化的蛋白质复合物的复杂细节。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号