首页> 外文期刊>American Journal of Infection Control >Evaluation of the survivability of MS2 viral aerosols deposited on filtering face piece respirator samples incorporating antimicrobial technologies.
【24h】

Evaluation of the survivability of MS2 viral aerosols deposited on filtering face piece respirator samples incorporating antimicrobial technologies.

机译:评估结合了抗菌技术的过滤面罩呼吸器样品上沉积的MS2病毒气溶胶的生存能力。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND: Respiratory protective devices exposed to pathogenic microorganisms present a potential source of transmission of infection during handling. In this study, the efficacy of 4 antimicrobial respirators to decontaminate MS2, a surrogate for pathogenic viruses, was evaluated and compared with control N95 filtering face piece respirators, which did not contain any known antimicrobial components. METHODS: MS2 containing droplet nuclei were generated using a Collison nebulizer and loaded onto respirator coupons at a face velocity of 13.2 cm/seconds for 30 minutes. The coupons were incubated at 2 different temperature and relative humidity (RH) conditions and analyzed for viable MS2 at different time intervals. RESULTS: Results showed that log(10) reduction of MS2 was not statistically significant (P > .05) between the control and antimicrobial respirator coupons, when stored at 22 degrees C and 30% RH up to 20 hours. Coupons from 1 of the 4 antimicrobial respirators showed an average MS2 log(10) reduction of 3.7 at 37 degrees C and 80% RH for 4 hours, which was statistically significant (P < or = .05) compared with coupons from the control respirators. CONCLUSION: Results from this study suggest that MS2 virus decontamination efficacy of antimicrobial respirators is dependent on the antimicrobial agent and storage conditions.
机译:背景:暴露于病原微生物的呼吸防护设备在处理过程中可能是传播感染的潜在来源。在这项研究中,评估了4种抗微生物呼吸器对MS2的净化效果,MS2是致病病毒的替代物,并与不含任何已知抗微生物成分的对照N95过滤式面罩呼吸器进行了比较。方法:使用Collison雾化器生成包含MS2的液滴核,并以13.2 cm / s的面速将其加载到防毒面具上30分钟。将试样在2个不同的温度和相对湿度(RH)条件下孵育,并在不同的时间间隔分析可行的MS2。结果:结果显示,当在22摄氏度和30%相对湿度下保存20小时时,对照和抗菌防毒面具之间的MS2的log(10)降低在统计学上无统计学意义(P> .05)。 4个抗菌防毒口罩中的1个的优惠券显示,在37摄氏度和80%RH下4小时的平均MS2 log(10)降低3.7,与对照组防毒面具的优惠券相比,具有统计学意义(P <或= .05) 。结论:这项研究的结果表明,抗微生物呼吸器的MS2病毒去污效果取决于抗微生物剂和储存条件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号