A rapid ion-exclusion chromatographic method with conductimetric detection for the determination of the main carboxylic acids (citric, tartaric, malic, fumaric, succinic, lactic, formic and acetic acids) in "Brandy de Jerez" is described. In order to increase the detection sensitivity, a pH 6.5 buffer Is added to the column effluent to ensure that the analytes are ionized. The linearity, sensitivity and repeatibility were evaluated for each acid. Detection limits ranging from 43.054 mg/L (acetic acid) to 0.732 mg/L (succinic acid) were obtained. The ion exclusion with "post-column" buffering and conductimetric detection permits the analysis of brandies without interferences from sugars and phenolic compounds. [References: 15]
机译:描述了一种用电导检测的快速离子排斥色谱法,用于测定“ Brandy de Jerez”中的主要羧酸(柠檬酸,酒石酸,苹果酸,富马酸,琥珀酸,乳酸,甲酸和乙酸)。为了提高检测灵敏度,将pH 6.5缓冲液添加到色谱柱流出物中,以确保分析物被离子化。评估每种酸的线性,灵敏度和重复性。获得的检出限为43.054 mg / L(乙酸)至0.732 mg / L(琥珀酸)。带有“柱后”缓冲和电导检测的离子排除技术可以分析白兰地,而不受糖和酚类化合物的干扰。 [参考:15]