...
首页> 外文期刊>American Journal of Orthodontics and Dentofacial Orthopedics >Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts
【24h】

Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts

机译:与数字铸模相比,锥束计算机断层扫描在牙科模型上进行线性测量的可重复性和准确性

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction The aim of this study was to determine the reproducibility and accuracy of linear measurements on 2 types of dental models derived from cone-beam computed tomography (CBCT) scans: CBCT images, and Anatomodels (InVivoDental, San Jose, Calif); these were compared with digital models generated from dental impressions (Digimodels; Orthoproof, Nieuwegein, The Netherlands). The Digimodels were used as the reference standard. Methods The 3 types of digital models were made from 10 subjects. Four examiners repeated 37 linear tooth and arch measurements 10 times. Paired t tests and the intraclass correlation coefficient were performed to determine the reproducibility and accuracy of the measurements. Results The CBCT images showed significantly smaller intraclass correlation coefficient values and larger duplicate measurement errors compared with the corresponding values for Digimodels and Anatomodels. The average difference between measurements on CBCT images and Digimodels ranged from -0.4 to 1.65 mm, with limits of agreement values up to 1.3 mm for crown-width measurements. The average difference between Anatomodels and Digimodels ranged from -0.42 to 0.84 mm with limits of agreement values up to 1.65 mm. Conclusions Statistically significant differences between measurements on Digimodels and Anatomodels, and between Digimodels and CBCT images, were found. Although the mean differences might be clinically acceptable, the random errors were relatively large compared with corresponding measurements reported in the literature for both Anatomodels and CBCT images, and might be clinically important. Therefore, with the CBCT settings used in this study, measurements made directly on CBCT images and Anatomodels are not as accurate as measurements on Digimodels.
机译:引言这项研究的目的是确定在两种类型的源自锥形束计算机断层扫描(CBCT)扫描的牙科模型上的线性测量的可重复性和准确性:CBCT图像和Anatomodels(InVivoDental,加利福尼亚州圣何塞);将这些与牙科印模生成的数字模型(Digimodels; Orthoproof,Nieuwegein,荷兰)进行了比较。 Digimodels被用作参考标准。方法从10位受试者中建立3种数字模型。四名检查员重复了37次线性牙齿和牙弓测量,测量了10次。进行配对的t检验和组内相关系数,以确定测量的可重复性和准确性。结果与Digimodels和Anatomodels的相应值相比,CBCT图像显示出明显更小的类内相关系数值和更大的重复测量误差。 CBCT图像和Digimodels上的测量值之间的平均差为-0.4到1.65 mm,对于冠宽测量值,协议值的限制最大为1.3 mm。 Anatomodels和Digimodels之间的平均差在-0.42至0.84 mm的范围内,协议值的限制最大为1.65 mm。结论发现在Digimodels和Anatomodels上的测量值之间以及Digimodels和CBCT图像之间的测量值具有统计学意义上的显着差异。尽管平均差异可能在临床上是可以接受的,但与文献中报道的有关Anatomodel和CBCT图像的相应测量相比,随机误差相对较大,在临床上可能很重要。因此,使用本研究中使用的CBCT设置,直接在CBCT图像和Anatomodels上进行的测量不如在Digimodels上进行的测量准确。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号