Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions

机译:从海藻酸盐印模的口内和锥形束计算机断层摄影扫描获得的数字模型上进行线性测量的有效性,可靠性和可重复性

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction: Digital 3-dimensional models are widely used for orthodontic diagnosis. The aim of this study was to assess the validity, reliability, and reproducibility of digital models obtained from the Lava Chairside Oral scanner (3M ESPE, Seefeld, Germany) and cone-beam computed tomography scans of alginate impressions for tooth-width measurements and the Bolton analysis. Methods: A digital model, an intraoral scan, and a plaster model were made for each of 22 subjects. Tooth-width measurements on the digital model and the intraoral scan were compared with those on the corresponding plaster models (gold standard). Intraclass correlation coefficients were calculated to determine the interexaminer reliability of the measurements of each method. The anterior and overall Bolton ratios were calculated for each participant and for each method. The paired t test was used to determine the validity. The scanning time for the intraoral scanner was registered and analyzed. Results: Tooth-width measurements of each tooth on the digital models and the intraoral scans did not differ significantly from those on the plaster models (P >0.05). The overall and anterior Bolton ratios from the 2 types of digital models differed significantly from the gold standard (P <0.05). However, the differences never exceeded 1.5 mm; this could be regarded as clinically insignificant. The scanning times of the intraoral scanner decreased significantly with the number of scans performed. Conclusions: Both intraoral scanning and cone-beam computed tomography scanning of alginate impressions are valid, reliable, and reproducible methods to obtain dental measurements for diagnostic purposes.
机译:简介:数字3维模型被广泛用于正畸诊断。这项研究的目的是评估从Lava Chairside口腔扫描仪(3M ESPE,Seefeld,德国)获得的数字模型的有效性,可靠性和可重复性,以及对藻酸盐压痕进行锥束计算机断层扫描,以进行牙齿宽度测量和博尔顿分析。方法:对22名受试者分别建立数字模型,口腔内扫描和石膏模型。将数字模型和口腔内扫描的牙齿宽度测量值与相应的石膏模型(黄金标准)进行了比较。计算组内相关系数以确定每种方法的测量的内部检验者可靠性。计算每个参与者和每种方法的前波尔顿和总波尔顿比。配对t检验用于确定有效性。记录并分析了口腔内扫描仪的扫描时间。结果:在数字模型和口腔内扫描中,每颗牙齿的齿宽测量值与石膏模型上的测量值无显着差异(P> 0.05)。两种数字模型的整体和前部Bolton比率与黄金标准有显着差异(P <0.05)。但是,差异从未超过1.5毫米。这在临床上可以忽略不计。口腔扫描仪的扫描时间随着扫描次数的增加而显着减少。结论:海藻酸盐印模的口腔内扫描和锥形束计算机断层扫描均是有效,可靠且可重现的方法,可用于获得用于诊断目的的牙齿测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号