首页> 外文期刊>日本セラミックス協会学術論文誌 >Thermal Conductivity Measurements of Float Glass at High Temperatures by Needle Probe Method
【24h】

Thermal Conductivity Measurements of Float Glass at High Temperatures by Needle Probe Method

机译:用针探针法在高温下的浮法玻璃的热导电测量

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Thermal conductivity of several soda-lime-silicate glasses, which are called float glasses, has been measured by a needle probe method in the temperature ranges from room temperature to 1173 K. Kinds of the samples were the ordinary clear float glass (CFL), bronze (BFL), gray (GFL), blue (HFL) and green (MFL) glasses. Experimental results showed that the thermal conductivity of the glasses increased gradually with rise of temperature in the ranges form room temperature to 1173 K. thermal conductivity values of the glasses measured do not depend on the kinds of samples, and it is considered that the measured values are real thermal conductivity. The values of conductivity of the glasses measured were about 1.0 W/(m centre dotK) at 303 K, 1.3 W/(m centre dot K) at 973 K and 1.7 W/(m centre dot K) at 1173 K.
机译:几种称为浮动玻璃的几种钠钙硅酸盐玻璃的导热率通过从室温至1173k的温度范围内的针头探针方法测量。种类的样品是普通透明浮法玻璃(CFL), 青铜(BFL),灰色(GFL),蓝色(HFL)和绿色(MFL)眼镜。 实验结果表明,玻璃的导热系数随着温度的升高而形成室温至1173k。测量的眼镜的导热率值不依赖于样品的种类,并且认为测量值 是真正的导热率。 测量的眼镜的电导率值在1173k的973k和1.7W /(M中心点K)下为303k,1.3W /(m中心点K)。