首页> 外文期刊>材料と環境 >Comparative Study on Electrochemical Behavior of Copper Tubes in Moundless Pitting and Pitting-Free Area's Tap Water
【24h】

Comparative Study on Electrochemical Behavior of Copper Tubes in Moundless Pitting and Pitting-Free Area's Tap Water

机译:铜管在无烟型近距区自来水中电化学行为的比较研究

获取原文
获取原文并翻译 | 示例
       

摘要

The pitting corrosion of copper tubes in tap water has been investigated by electrochemical measurements. Measurements of corrosion potentials, potentiodynamic polarization tests and potentiostatic corrosion tests were carried out in two types of tap water: one type of water was taken in the area where the moundless pitting has occurred (called as 'pitting area's water') and another type was taken in the area where the pitting has not occurred (called as 'pitting-free area's water'). The corrosion potential in pitting area's water was higher than that in pitting-free area's water and shifted to a nobler value gradually. Current densities of pitting area's water also indicated higher values than those of pitting-free area's water in both polarization tests and corrosion potentiostatic tests. Many visible pits existed on the surface of the specimen after the potentiostatic tests at 200 mV (Ag/AgCl) in pitting area's water.
机译:通过电化学测量研究了自来水中铜管的点蚀腐蚀。 腐蚀电位的测量,电位动力学偏振试验和电位腐蚀试验在两种类型的自来水中进行:在发生丘疹蚀的区域(称为'挂点的水')和另一种类型是 拍摄在何时没有发生的地区(称为“无点蚀地区的水”)。 点蚀地区的水中的腐蚀潜力高于无点蚀地区的水中的水,逐渐转移到更高劣的值。 斑点的水的电流密度也表明了偏振试验和腐蚀电位试验中无点蚀区域的水的值更高。 在Pitting区域的水中200mV(Ag / AgCl)的电位试验后,样品表面上存在许多可见坑。