...
首页> 外文期刊>Diabetes technology & therapeutics >Glycemic Variability Percentage: A Novel Method for Assessing Glycemic Variability from Continuous Glucose Monitor Data
【24h】

Glycemic Variability Percentage: A Novel Method for Assessing Glycemic Variability from Continuous Glucose Monitor Data

机译:血糖可变性百分比:一种评估连续葡萄糖监测数据的血糖变异的新方法

获取原文
获取原文并翻译 | 示例

摘要

Background: High levels of glycemic variability are still observed in most patients with diabetes with severe insulin deficiency. Glycemic variability may be an important risk factor for acute and chronic complications. Despite its clinical importance, there is no consensus on the optimum method for characterizing glycemic variability. Method: We developed a simple new metric, the glycemic variability percentage (GVP), to assess glycemic variability by analyzing the length of the continuous glucose monitoring (CGM) temporal trace normalized to the duration under evaluation. The GVP is similar to other recently proposed glycemic variability metrics, the distance traveled, and the mean absolute glucose (MAG) change. We compared results from distance traveled, MAG, GVP, standard deviation (SD), and coefficient of variation (CV) applied to simulated CGM traces accentuating the difference between amplitude and frequency of oscillations. The GVP metric was also applied to data from clinical studies for the Dexcom G4 Platinum CGM in subjects without diabetes, with type 2 diabetes, and with type 1 diabetes (adults, adolescents, and children). Results: In contrast to other metrics, such as CV and SD, the distance traveled, MAG, and GVP all captured both the amplitude and frequency of glucose oscillations. The GVP metric was also able to differentiate between diabetic and nondiabetic subjects and between subjects with diabetes with low, moderate, and high glycemic variability based on interquartile analysis. Conclusion: A new metric for the assessment of glycemic variability has been shown to capture glycemic variability due to fluctuations in both the amplitude and frequency of glucose given by CGM data.
机译:背景:在大多数患有严重胰岛素缺乏的糖尿病患者中仍观察到高水平的血糖变异性。血糖可变性可能是急性和慢性并发症的重要危险因素。尽管临床重要性,但对特征血糖变异性的最佳方法没有共识。方法:我们开发了一种简单的新度量,血糖可变性百分比(GVP),通过分析在评估下持续时间的连续葡萄糖监测(CGM)时间痕量的长度来评估血糖变异性。 GVP类似于最近提出的血糖可变度量,行进距离,以及平均绝对葡萄糖(MAG)变化。我们与距离,MAG,GVP,标准偏差(SD)的结果进行比较,以及应用于模拟CGM迹线的变异系数(CV),突出振荡振荡频率之间的差异。 GVP指标也应用于来自没有糖尿病的受试者德克斯康G4铂CGM的临床研究的数据,患有2型糖尿病,以及1型糖尿病(成人,青少年和儿童)。结果:与其他度量相比,如CV和SD,行进的距离,MAG和GVP都捕获了葡萄糖振荡的幅度和频率。 GVP指标还能够区分糖尿病和非糖尿病受试者,以及基于四分位分析的低,中等和高血糖可变性的糖尿病之间的受试者。结论:评估血糖变异评估的新指标由于CGM数据给出的葡萄糖幅度和频率的波动而捕获血糖可变性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号