Comparison of Syringe Compression Force Between ENFit and Legacy Feeding Tubes

机译:依烯件和遗留馈电管中注射器压缩力的比较

获取原文
获取原文并翻译 | 示例

摘要

Background: Since initial report in 1972, misconnections continue to be an issue, especially in hospitalized patients with multiple access devices. A new small-bore connector standard (ENFit) has been proposed in order to minimize misconnections. Methods: Commercially available finalized ENFit tubes of a variety of sizes (14 French [Fr] size, 18Fr, 20Fr, 24Fr, and low-profile) were obtained for current testing. Variety of commercially available formulas including blenderized tube feeding (BTF) products (Jevity 1 Cal, Abbott Nutrition, Abbott Park, IL; Nourish, Functional Formularies, Centerville, OH; Real Food Blends, Chesterton, IN) were tested. Results: Data from individual measurements were aggregated for ENFit and legacy tubes and revealed higher syringe compression force in legacy tubes compared with ENFit tubes for 20Fr size with Jevity formula. Our institution's BTF formula revealed that legacy tubes had lower syringe compression force than ENFit tubes for 14Fr tube size. Remaining measurements revealed no significant difference. Model 1 of regression analysis revealed that only formula and tube size were significant with R-2 of 0.63. Model 2 evaluating the impact of tube size, blender, time of blending, and legacy vs ENFit revealed that tube size, blender used, and blending time were significant with legacy vs ENFit being nonsignificant (R-2 of 0.72). Conclusions: Overall, only a small number of tube sizes (14Fr and 20Fr) with selected formulas revealed a significant difference between ENFit and Legacy tubes, with remaining studies finding no significant difference. Regression analysis revealed that variables such as formula, size of tube, blender used, and time of blending may have more impact on compression force.
机译:背景:自1972年的初始报告以来,误报继续成为一个问题,特别是在住院患者的多种接入设备中。已经提出了一种新的小钻孔连接器标准(ENFIT)以最大限度地减少误差。方法:获得各种尺寸的市售最终确定的素管(14种French [Fr]尺寸,18FR,20FR,24FR和低调)进行电流测试。各种市售公式,包括模糊的管饲料(BTF)产品(JEVITY 1 CAL,Abbott Nutrition,Abbott Park,IL;滋养,功能性漂种,Centerville,OH;真正的食物混合物,叶蛋白,Checherton,In)进行了测试。结果:各个测量的数据被聚集成用于enFit和遗留管,并在与Jevity公式的20FR尺寸的浓度管相比,遗留管中显示出较高的注射器压缩力。我们的机构的BTF公式显示,遗留管的注射器压缩力比为14FR管尺寸的烯件压缩力。剩余的测量显示没有显着差异。回归分析的型号1显示,只有0.63的R-2只有公式和管尺寸显着。模型2评估管尺寸,混合,混合时间和传统VS enfit的影响显示,使用管尺寸,使用的搅拌器和混合时间与遗留VS enfit不显着(R-2为0.72)。结论:总体而言,只有少量的管尺寸(14FR和20FR),具有选定的公式揭示了基因和遗留管之间的显着差异,并且剩余的研究发现没有显着差异。回归分析显示,如公式,管,使用的搅拌器和混合时间的变量可能对压缩力产生更多的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号