首页> 外文期刊>Journal of the Iranian Chemical Society >SBA-15/Metformin as a novel sorbent combined with surfactant-assisted dispersive liquid-liquid microextraction (SA-DLLME) for highly sensitive determination of Pb, Cd and Ni in food and environmental samples
【24h】

SBA-15/Metformin as a novel sorbent combined with surfactant-assisted dispersive liquid-liquid microextraction (SA-DLLME) for highly sensitive determination of Pb, Cd and Ni in food and environmental samples

机译:SBA-15 /二甲双胍作为一种新型吸附剂,与表面活性剂辅助分散液 - 液体微萃取(SA-DLLME)结合食物和环境样品中的PB,CD和Ni的高敏感测定

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This paper established a new, rapid and sensitive method for the ultra-trace determination of lead, cadmium and nickel in food and environmental samples preconcentrated by dispersive solid-phase extraction (DSPE) combined with surfactant-assisted dispersive liquid-liquid microextraction (SA-DLLME) prior to graphite furnace atomic absorption spectrometry. SBA-15/Met was synthesized and used as a new efficient sorbent for the extraction of metal ions in DSPE. It was characterized by TEM and TGA techniques. After DSPE step, stripped metal elements were complexed with dithizone, and then, the complexes were extracted into carbon tetrachloride by using SA-DLLME. A conventional nonionic surfactant, triton X-100 was used as a disperser agent. Under the optimized conditions, the limit of quantifications was found to be 2.5 ng L-1 for Pb2+, Cd2+ and 5.0 ng L-1 for Ni2+. The limits of detection were 1.5 ng L-1 for Ni2+ and 0.75 ng L-1 for Pb2+ and Cd2+, with enrichment factor of 1650. The optimized method exhibited a good precision level with relative standard deviations (RSDs%) values of 4.9, 5.2 and 5.0% for 1 mu g L-1 Pb2+, Cd2+ and Ni2+, respectively (n = 7). Application of the proposed method to the analysis of fish-certified reference material produced results that were in good agreement with the certified values.
机译:本文建立了一种新的,快速敏感的方法,用于通过分散固相萃取(DSPE)与表面活性剂辅助分散液 - 液微萃取(SA- DLLME)在石墨炉原子吸收光谱谱系之前。 SBA-15 / Met被合成并用作新的高效吸附剂,用于在DSPE中提取金属离​​子。它的特点是TEM和TGA技术。在DSPE步骤之后,用二硫醚络合剥离的金属元素,然后通过使用SA-DLLME将络合物萃取到四氯化碳中。传统的非离子表面活性剂,Triton X-100用作分散剂剂。在优化的条件下,对于Ni2 +的Pb2 +,Cd2 +和5.0ng L-1,将定量限为2.5ng L-1。对于PB2 +和CD2 +的Ni2 +和0.75ng L-1的检测限为1.5ng L-1,富集因子为1650.优化方法表现出良好的精度水平,相对标准偏差(RSD%)值为4.9,5.2分别为1 mu g l-1 pb2 +,cd2 +和ni2 +的5.0%(n = 7)。提出的方法在分析鱼认证的参考资料分析中,产生了与认证价值吻合良好的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号