Initial Benchmarking of the Liquid Sampling-Atmospheric Pressure Glow Discharge-Orbitrap System Against Traditional Atomic Mass Spectrometry Techniques for Nuclear Applications

机译:液体采样 - 大气压辉光辐射排放 - 核应用传统原子质谱技术的初始基准

获取原文
获取原文并翻译 | 示例
           

摘要

The integration of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ion source with Orbitrap mass spectrometers has resulted in new opportunities in the field of isotope ratio mass spectrometry. In a field that has been dominated by thermal ionization mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICP-MS) on quadrupole and scanning-mode sector field analyzer platforms for highly accurate and precise measurements, the LS-APGD-Orbitrap system offers a benchtop instrument capable of meeting the rigorous International Target Values for measurement uncertainty for uranium (U). In order to benchmark the LS-APGD-Orbitrap, a series of U certified reference materials with increasing U-235 isotopic composition were analyzed. By using U samples ranging in enrichment from 1 to 80%, the ability of the system to measure isotope ratios over a wide range is demonstrated. This analysis represents the first time that the LS-APGD-Orbitrap system has been used to analyze highly enriched U samples, allowing for the measurement of each of the U isotopes, including U-234 and U-236-related species, which had not been achieved previously. Ultimately, the LS-APGD-Orbitrap system was able to measure CRM U-800 (assayed as U-235 / U-238 = 4.265622) as 4.266922, with a combined uncertainty, (u(c)), of 0.040%. These results are compared to those obtained using traditional elemental mass spectrometers including TIMS and ICP-MS-based instruments. The effectiveness of the LS-APGD-Orbitrap MS system for measuring U isotopes shows excellent promise in nuclear forensics, safeguards, and other nuclear weapon-based applications.
机译:液体采样大气压辉光放电(LS-APGD)离子源的整合与侧面光谱仪导致同位素比质谱法领域的新机会。在一支由热电电离质谱(TIMS)和电感耦合的等离子体质谱(ICP-MS)上以高压杆和扫描模式扇区分析仪平台为主的领域,用于高精度和精确测量,LS-APGD-Orbitrap系统提供一个能够满足铀(U)测量不确定性的严格国际目标值的台式仪器。为了基准测试LS-APGD-ORBITRAP,分析了一系列U-235同位素组合物的U认证参考材料。通过使用富集的U样品从1〜80%的富集,证明了系统测量同位素比在宽范围内的能力。该分析代表了LS-APGD-orbitrap系统的第一次用于分析高度富集的U样品,允许测量每个同位素,包括U-234和U-236相关的物种,其没有以前取得了成就。最终,LS-APGD-orbitrap系统能够测量CRM U-800(测定为U-235 / U-238 = 4.265622),为4.266922,具有组合的不确定性(U(C)),0.040%。将这些结果与使用传统元素质谱仪获得的结果进行比较,包括TIMS和ICP-MS的仪器。测量U同位素的LS-APGD-orbitrap MS系统的有效性在核法医,保障和其他基于核武器的应用中显示出优异的承诺。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号