A Comparative Evaluation of Stress Distribution with Two Attachment Systems of Varying Heights in a Mandibular Implant-Supported Overdenture: A Three-Dimensional Finite Element Analysis

机译:颌骨植入覆盖用两个附着体系的应力分布的比较评估:三维有限元分析

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose To analyze and compare the stress distribution in an implant-retained overdenture complex using ball and Locator attachments of three heights by means of a 3D finite element analysis (FEA). Materials and Methods Six finite element models comprising an edentulous mandible with two interforaminal bone-level implants and ball attachments of heights 1 mm (A1), 3 mm (A3), and 5 mm (A5), and Locator attachments of heights 1 mm (B1), 3 mm (B3), and 5 mm (B5), were designed using ANSYS Workbench Software. Unilateral vertical (100 N) and oblique loads (100 N at 30 degrees to the longitudinal axis of the implant in buccolingual direction) were applied. Average von Mises stress values were evaluated quantitatively and qualitatively. Results Locator attachments showed lower stress values as compared to the ball attachments in all examined areas. The increase in the height of both resulted in increased stress values. Higher values were observed at the implant neck in all models, as compared to the body and the apex. The recorded stress was higher in the cortical bone as compared to the cancellous bone. Conclusions Within the limitations of the study, Locator attachments demonstrated lesser and more homogenous stress distribution in the implant-overdenture complex in comparison to ball attachments. The stresses generated within the tissues increase with an increase in collar height of the attachment system and therefore, attachments should be as short as possible for more favorable stress transmission.
机译:目的通过通过3D有限元分析(FEA)使用三个高度的球和定位器附件来分析和比较植入物覆盖复合物中的应力分布。材料和方法六个有限元模型,包括具有两个骨干骨液位植入物的薄颌骨和高度1mm(a1),3mm(a3)和5mm(a5)的球连接,以及高度1 mm的定位器附件(使用ANSYS Workbench软件设计B1),3毫米(B3)和5毫米(B5)。施加单侧垂直(100n)和倾斜载荷(100n以30度到植入物的植入方向的纵向轴线)。量化和定性评估平均von误法应力值。结果定位器附件与所有检查区域中的球连接相比,应力值较低。两者的高度的增加导致应力值增加。与身体和顶点相比​​,在所有型号的植入物颈部观察到较高的值。与松质骨相比,皮质骨中记录的应力较高。结论在研究的局限内,定位器附件与球连接相比,定位器附件在植入物覆盖复合物中展示了较小的植入物复合物。在组织内产生的应力随着附接系统的套环高度的增加而增加,因此,对于更有利的应力传输,附件应该尽可能短。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号