New fluorescent method (PLT-F) on sysmex XN2000 hematology analyzer achieved higher accuracy in low platelet counting

机译:sysmex XN2000血液分析仪上的新荧光方法(PLT-F)在低血小板计数中获得了更高的准确性

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Objectives: In thrombocytopenia, high accuracy and precision of low platelet count is essential for appropriate decisions. The recently introduced Sysmex XN2000 analyzer (Sysmex, Kobe, Japan) offers 3 methods for platelet counting: impedance (PLT-I), optical (PLT-O), and a new fluorescence method (PLT-F). The precision of the PLT-F method in blood samples with platelet counts less than 50 ×103/μL (50 × 109/L) was investigated and compared with the ICSH CD61- ImmunoPLT reference method. For comparison, PLT-I and PLT-O were determined on the Sysmex XN2000 and Sysmex XE2100 analyzer. Methods: Blood samples with platelet counts less than 50 ×103/μL (50 × 109/L) (n = 37) were analyzed on the Sysmex XN2000 and XE2100 analyzers. The CD61-ImmunoPLT method was performed on a Beckman Coulter FC-500 flow cytometer (Miami, FL). Results: At a platelet count of 20 ×103/μL (20 × 109/L), reproducibility for PLT-I, PLT-O, and PLT-F on the XN2000 demonstrated coefficients of variation of 9.3%, 8.5%, and 3.0%, respectively. Correlation between PLT-O on the XN2000 and XE2100 yielded an r value of more than 0.977. Linear regression analysis between the PLT-F and CD61- ImmunoPLT methods resulted in a PLT-F of 0.71*CD61 - 0.8 (r = 0.988). Linear regression between PLT-F and PLT-O on the XN2000 resulted in a PLT-F of 1.05 PLT-O - 2 (r = 0.975), and using the transfusion threshold of 20 × 109/L platelets resulted in a PLT-F of 0.90*PLT-O - 0.4 (r = 0.956). Conclusions: The new PLT-F method demonstrated excellent results for reproducibility in samples with platelet counts less than 50 × 109/L. PLT-F could be helpful in making better decisions for platelet transfusions.
机译:目的:在血小板减少症中,血小板计数低的高精度和高精度对于做出适当的决定至关重要。最近推出的Sysmex XN2000分析仪(Sysmex,神户,日本)提供了三种血小板计数方法:阻抗(PLT-1),光学(PLT-0)和新的荧光法(PLT-F)。研究了血小板计数小于50×103 /μL(50×109 / L)的血液样本中PLT-F方法的精度,并将其与ICSH CD61-ImmunoPLT参考方法进行了比较。为了进行比较,在Sysmex XN2000和Sysmex XE2100分析仪上确定了PLT-1和PLT-O。方法:在Sysmex XN2000和XE2100分析仪上分析血小板计数低于50×103 /μL(50×109 / L)(n = 37)的血液样本。 CD61-ImmunoPLT方法在Beckman Coulter FC-500流式细胞仪(佛罗里达州迈阿密)上进行。结果:在血小板计数为20×103 /μL(20×109 / L)时,XN2000上PLT-1,PLT-O和PLT-F的重现性显示变异系数为9.3%,8.5%和3.0 %, 分别。 XN2000和XE2100上的PLT-O之间的相关性得出r值大于0.977。 PLT-F和CD61-ImmunoPLT方法之间的线性回归分析得出PLT-F为0.71 * CD61-0.8(r = 0.988)。 XN2000上PLT-F和PLT-O之间的线性回归导致PLT-F为1.05 PLT-O-2(r = 0.975),使用20×109 / L血小板的输注阈值得到PLT-F 0.90 * PLT-0-0.4(r = 0.956)。结论:新的PLT-F方法在血小板计数小于50×109 / L的样品中具有出色的重现性结果。 PLT-F有助于做出更好的血小板输注决策。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号