...
首页> 外文期刊>Journal of nuclear medicine technology >Comparison of Step-and-Shoot and Continuous-Bed-Motion PET Modes of Acquisition for Limited-View Organ Scans
【24h】

Comparison of Step-and-Shoot and Continuous-Bed-Motion PET Modes of Acquisition for Limited-View Organ Scans

机译:用于限量视图器官扫描的阶梯和连续卧床运动PET模式的比较

获取原文
获取原文并翻译 | 示例

摘要

Continuous-bed-motion (CBM) acquisition mode has been made commercially available in PET/CT scanners. CBM mode is designed for whole-body imaging, with a long scan length (multiple axial fields of view [aFOVs]) and short acquisition duration (2-3 min/aFOV). PET/CT has recently been used after ~(90)Y-micro-sphere therapy to quantify ~(90)Y activity distribution in the liver. Here we compared counting efficiencies along the bed-motion direction (z-axis) between CBM and step-and-shoot (SS) acquisition modes for limited-view organ scans, such as ~(90)Y PET/CT liver studies, that have short scan lengths (<2 aFOVs) and long acquisition durations (10-30 min/aFOV). Methods: The counting efficiencies, that is, analytic sensitivities, in SS mode (single-aFOV and multiple-aFOV scans) and CBM mode were theoretically derived and experimentally validated using a cylindric ~(68)Ge phantom. The sensitivities along the z-axis were compared between the SS and CBM modes. Results: The analytic and experimental count profiles were in good agreement, validating the analytic models. For fixed scan durations, the overall coincidence counting efficiency in CBM mode was lower (~60%) than those in SS modes, and the maximum sensitivity in CBM mode was 50% or less of that in 1 -aFOV SS mode and 100% or less of that in 2-aFOV SS mode. Conclusion: The ability of CBM mode to tailor-fit the PET/CT scan length and local scan duration is not realized in studies with a short scan length (<30 cm) and long scan duration (20 min/aFOV for the scanner). SS acquisition mode is preferable to CBM mode for limited-view organ and count-starved scans, such as ~(90)Y PET/CT liver scans, because of the higher counting efficiency of SS mode, which leads to better image quality and quantification precision.
机译:连续床 - 运动(CBM)采集模式已在PET / CT扫描仪中商购获得。 CBM模式专为全身成像而设计,具有长扫描长度(多个轴向视野[AFOVS])和短收集持续时间(2-3分钟/ AFOV)。最近在〜(90)Y微球疗法后使用PET / CT以定量肝脏中的〜(90)Y活性分布。在这里,我们将CBM和步进 - 拍摄(SS)采集模式之间的床 - 运动方向(Z轴)进行比较计数效率,用于有限视图器官扫描,例如〜(90)Y宠物/ CT肝脏研究,即具有短扫描长度(<2 AFOV)和长采集持续时间(10-30分钟/ AFOV)。方法:在理论上派生和通过圆柱〜(68)Ge Phantom理论上验证和实验验证的计数效率,即分析灵敏度,在SS模式下(单次AFOV和多AFOV扫描)和CBM模式。在SS和CBM模式之间比较沿Z轴的敏感性。结果:分析和实验计数型材非常一致,验证分析模型。对于固定扫描持续时间,CBM模式的整体重合计数效率低于SS模式的较低(〜60%),CBM模式中的最大灵敏度为1-afov SS模式和100%或100%或在2-AFOV SS模式下少。结论:CBM模式定制拟合PET / CT扫描长度和局部扫描持续时间的能力在短扫描长度(<30cm)和长扫描持续时间(20分钟/扫描仪)的研究中不实现。 SS采集模式对于限量视图器官和计数扫描的CBM模式是优选的,例如〜(90)y PET / CT肝脏扫描,因为SS模式的计数效率较高,这导致更好的图像质量和量化精确。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号