Comparison of Step-and-Shoot and Continuous-Bed-Motion PET Modes of Acquisition for Limited-View Organ Scans

机译:有限视野器官扫描的步进式和连续床式PET采集模式的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Continuous-bed-motion (CBM) acquisition mode has been made commercially available in PET/CT scanners. CBM mode is designed for whole-body imaging, with a long scan length (multiple axial fields of view [aFOVs]) and short acquisition duration (2–3 min/aFOV). PET/CT has recently been used after 90Y-microsphere therapy to quantify 90Y activity distribution in the liver. Here we compared counting efficiencies along the bed-motion direction (z-axis) between CBM and step-and-shoot (SS) acquisition modes for limited-view organ scans, such as 90Y PET/CT liver studies, that have short scan lengths (≤2 aFOVs) and long acquisition durations (10–30 min/aFOV). >Methods: The counting efficiencies, that is, analytic sensitivities, in SS mode (single-aFOV and multiple-aFOV scans) and CBM mode were theoretically derived and experimentally validated using a cylindric 68Ge phantom. The sensitivities along the z-axis were compared between the SS and CBM modes. >Results: The analytic and experimental count profiles were in good agreement, validating the analytic models. For fixed scan durations, the overall coincidence counting efficiency in CBM mode was lower (∼60%) than those in SS modes, and the maximum sensitivity in CBM mode was 50% or less of that in 1-aFOV SS mode and 100% or less of that in 2-aFOV SS mode. >Conclusion: The ability of CBM mode to tailor-fit the PET/CT scan length and local scan duration is not realized in studies with a short scan length (≤30 cm) and long scan duration (20 min/aFOV for the scanner). SS acquisition mode is preferable to CBM mode for limited-view organ and count-starved scans, such as 90Y PET/CT liver scans, because of the higher counting efficiency of SS mode, which leads to better image quality and quantification precision.
机译:连续床移动(CBM)采集模式已在PET / CT扫描仪中商业化提供。 CBM模式专为全身成像而设计,具有较长的扫描长度(多个轴向视场[aFOVs])和较短的采集时间(2-3分钟/ aFOV)。最近,在 90 Y微球治疗后使用PET / CT量化肝脏中 90 Y活性的分布。在这里,我们比较了在受限视图器官扫描(例如 90 Y PET / CT)中,CBM和步进拍摄(SS)采集模式之间沿床运动方向(z轴)的计数效率肝脏研究,扫描长度短(≤2 aFOV),采集时间长(10–30 min / aFOV)。 >方法:理论上推导了SS模式(单aFOV和多次aFOV扫描)和CBM模式下的计数效率,即分析灵敏度,并使用圆柱 68 进行了实验验证sup>葛幻影。在SS模式和CBM模式之间比较了沿z轴的灵敏度。 >结果:分析和实验计数曲线吻合良好,验证了分析模型。对于固定扫描持续时间,CBM模式下的总体符合计数效率低于SS模式(〜60%),CBM模式下的最大灵敏度为1-aFOV SS模式下的最高灵敏度的50%或以下,而100%或100%更少于2-aFOV SS模式下的数据。 >结论:在扫描长度短(≤30cm)和扫描时间长(20 min)的研究中,无法实现CBM模式适应PET / CT扫描长度和局部扫描持续时间的能力/ aFOV(用于扫描仪)。对于有限视野的器官扫描和计数不足的扫描(例如 90 Y PET / CT肝脏扫描),SS采集模式优于CBM模式,因为SS模式的计数效率更高,因此效果更好图像质量和量化精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号