首页> 外文期刊>Journal of oral rehabilitation >Influence of short‐term side effects on oral sleep appliance compliance among CPAP‐intolerant patients: An objective monitoring of compliance
【24h】

Influence of short‐term side effects on oral sleep appliance compliance among CPAP‐intolerant patients: An objective monitoring of compliance

机译:短期副作用对CPAP - 不宽容患者口腔睡眠器具的影响:遵守的客观监测

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Objectives To investigate the predictive value of side effects on usage times during the initial titration phase of oral appliance therapy for sleep apnoea. The secondary objective was to assess the correlation between subjective and objective usage times. Methods A total of 21 subjects diagnosed with sleep apnoea and a history of non‐compliance with CPAP therapy were enrolled in the 4‐week clinical study. Objective compliance was assessed through an intra‐oral compliance monitor embedded in a Thornton Adjustable Positioner. Subjective compliance was evaluated through self‐reporting and questionnaire for side effects. Results Excess salivation, xerostomia and tooth discomfort were the most common side effects (61%‐67%). Noises (OR?=?10, 95% CI?=?0.85‐117.02, P ?=?0.067), jaw discomfort (OR?=?15, 95% CI?=?1.21‐185.20, P ?=?0.035) and gum discomfort (OR?=?8.86, 95% CI?=?1.0‐∞, P ?=?0.038) were highly predictive of non‐compliance. Subjects with either “none” or “mild” side effects recorded a mean oral appliance usage time ≥5.5?hours/night, while subjects reporting “severe” side effects recorded a mean usage time ≤4?hours/night. The mean usage time was 5.49?hours/night, with nightly compliance (defined as 4?hours per night for 70% the nights per week) at 33%. Nonetheless, compliance increased from 26%‐50% from week 1 to week 4. The subjective and objective usage times were highly correlated ( r ?=?0.81). Conclusions There was a high correlation between subjective and objective compliance reporting data. Moderate/severe side effects had the greatest effect on compliance.
机译:摘要目的,研究睡眠呼吸暂停口服疗法初始滴定阶段副作用的预测值。二级目标是评估主观和客观使用时间之间的相关性。方法患有睡眠呼吸暂停的21项受试者和不符合CPAP疗法的历史记录4周的临床研究。通过嵌入Thornton可调节定位器中的口腔口腔合规显示器来评估客观依从性。通过自我报告和调查问卷进行主观合规性进行副作用。结果施加过多,Xerostomia和牙齿不适是最常见的副作用(61%-67%)。噪音(或?=?10,95%ci?= 0.85-117.02,p?= 0.067),下颚不适(或?=?15,95%ci?=?1.21-185.20,p?= 0.035)和牙龈不适(或?=α= 8.86,95%ci?=?1.0-∞,p?= 0.038)是高度预测的不合规性。具有“无”或“轻度”副作用的受试者记录了平均口头家电使用时间≥5.5?小时/夜,而受试者报告“严重”副作用记录了平均使用时间≤4小时/夜。平均使用时间为5.49?小时/夜,夜间合规(定义为每晚70%的每晚每晚每晚70%)。尽管如此,合规性从一周到第4周的26%-50%增加。主观和客观使用时间高度相关(R?= 0.81)。结论主观和客观合规性报告数据之间存在高相关性。适度/严重的副作用对遵守具有最大的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号