Impact of respiratory motion correction on SPECT myocardial perfusion imaging using a mechanically moving phantom assembly with variable cardiac defects

机译:用可变心脏缺陷机械移动模拟组装对呼吸运动校正对SPECT心肌灌注成像的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Background The aim of this study was to determine the impact of respiratory motion correction on SPECT MPI and on defect detection using a phantom assembly. Methods SPECT/CT data were acquired using an anthropomorphic phantom with inflatable lungs and with an ECG beating and moving cardiac compartment. The heart motion followed the respiratory pattern in the cranio-caudal direction to simulate normal or deep breathing. Small or large transmural defects were inserted into the myocardial wall of the left ventricle. SPECT/CT images were acquired for each of the four respiratory phases, from exhale to inhale. A respiratory motion correction was applied using an image-based method with transformation parameters derived from the SPECT data by a non-rigid registration algorithm. A report on defect detection from two physicians and a quantitative analysis on MPI data were performed before and after applying motion correction. Results Respiratory motion correction eliminated artifacts present in the images, resulting in a uniform uptake and reduction of motion blurring, especially in the inferior and anterior regions of the LV myocardial walls. The physicians’ report after motion correction showed that images were corrected for motion. Conclusions A combination of motion correction with attenuation correction reduces artifacts in SPECT MPI. AC-SPECT images with and without motion correction should be simultaneously inspected to report on small defects.
机译:摘要背景本研究的目的是确定呼吸运动校正对SPIT MPI的影响以及使用幻影组件的缺陷检测。方法使用具有充气肺的拟人幽灵和带有心电图和移动心脏隔室的拟人术语来获取SPECT / CT数据。心脏动作遵循颅骨方向上的呼吸模式,模拟正常或深呼吸。将小或大的透气缺陷插入左心室的心肌壁中。为四个呼吸阶段中的每一个获取SPECT / CT图像,从呼气吸入。使用基于图像的方法应用呼吸运动校正,该方法通过非刚性登记算法从SPECT数据导出的变换参数。在施加运动校正之前和之后,执行有关两种医生缺陷检测的报告和MPI数据的定量分析。结果呼吸运动校正消除了图像中存在的伪影,导致运动模糊的均匀摄取和减少,特别是在LV心肌壁的下部和前部区域中。运动校正后的医生报告显示,图像被纠正运动。结论运动校正与衰减校正的组合减少了SPECT MPI中的伪影。应同时检查具有和不带运动校正的AC-SPECT图像以报告小缺陷。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号