...
首页> 外文期刊>Journal of molecular histology >Correlation between three-dimensional power Doppler and morphometric measurement of endometrial vascularity at the time of embryo implantation in women with unexplained recurrent miscarriage
【24h】

Correlation between three-dimensional power Doppler and morphometric measurement of endometrial vascularity at the time of embryo implantation in women with unexplained recurrent miscarriage

机译:无知的复发流产胚胎胚胎胚胎植入时胚胎血管间质血管性形态测量的相关性

获取原文
获取原文并翻译 | 示例
           

摘要

Power Doppler in combination with three-dimensional (3D-PD) ultrasonography has been used as a noninvasive tool to evaluate the vascularity. However, it is unclear whether 3D-PD can accurately reflect endometrial vascularization and replace the invasive endometrial biopsy. This study aims to investigate the correlation between 3D-PD and micro vessel morphometric measurement of endometrial vascularity. Twenty-five women with unexplained recurrent miscarriage were recruited for 3D-PD and endometrial biopsy on precisely day LH + 7. Immunohistochemistry using vWF was employed to identify micro vessels in endometrial biopsy specimens followed by the use of morphometric technique to measure the mean vessel diameter and volume fractions. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) assessed by 3D-PD were calculated for both the endometrial and sub-endometrial regions. There were no significant correlations between any of the ultrasonographic measurements (endometrial thickness, endometrial volume, endometrial VI/FI/VFI, sub-endometrial volume, sub-endometrial VI/FI/VFI) and morphometric features (number of micro vessel, mean diameter of micro vessel and volume fraction measurement of vessel). This study indicates that endometrial vascularity assessed by 3D-PD could not be used to reflect changes in micro vessels of the endometrium at the time of embryo implantation in women with unexplained recurrent miscarriage.
机译:电源多普勒与三维(3D-PD)超声检查已被用作非侵入工具以评估血管性。然而,目前尚不清楚3D-PD是否可以精确地反映子宫内膜血管化并替换侵入性子宫内膜活检。本研究旨在探讨3D-Pd和微容器形态学测量子宫内膜血管性的相关性。招募了二十五名具有无法解释的复发性流产的妇女,促进3D-Pd和子宫内膜活检,精确的日子LH + 7.使用VWF的免疫组化用于鉴定子宫内膜活检标本中的微容器,然后使用形态测量技术测量平均血管直径和体积分数。用3D-Pd评估的血管化指数(VI),流量指数(FI)和血管化流量指数(VFI)用于子宫内膜和亚末端膜区域。任何超声测量(子宫内膜厚度,子宫内膜体积,子宫内膜VI / FI / FI / FI / FI / FI / FI / FI / FI / FI / FI / FI / FI / FI / FI / FI / FI / VFI)和形态学特征(微容量数,平均直径)之间没有显着的相关性血管的微容器和体积分数测量。该研究表明,3D-PD评估的子宫内膜血管性不能用于反映具有无法解释的经常性流产的妇女胚胎植入时胚胎植入时胚胎植入的微容器的变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号